Coolant recirculator
6 Installation
6 Installation
6.1 Installation
1
Heat exchanger
(finned radiator), 4-row
2
Coolant supply (blue)
3
Coolant return (red)
4
Tank
5
Motor with fan
6
Submergible pump
Fig. 5
Circuit diagram WK43 with flow control option
NOTICE
• We recommend to install a flow control in the coolant return to
permanently monitor the correct functioning of the entire cooling system.
Fig. 4 Circuit diagram WK23 with flow control option on page EN-10
and Fig. 5 Circuit diagram WK43 with flow control option on page EN-11
• In case of insufficient flow, the flow control causes the immediate switch-
off of the connected devices and prevents thermal overload.
1
2
3
4
6
5
CAUTION
Risk of toppling
Physical damage or damage to components due to improper mounting.
• Separate the supply lines.
• Place the components on a suitable base (flat, tight, dry) that prevents
them from tipping.