![background image](http://html1.mh-extra.com/html/abicor-binzel/tig-abitig-mt/tig-abitig-mt_operating-instructions-manual_3606223028.webp)
EN - 8
3 Product Description
ABITIG
®
MT
work. Keep appropriate fire extinguishing equipment ready in the
workplace.
2.6 Emergency information
In case of emergency, immediately interrupt the following supplies:
• Electricity, compressed air, gas
Further measures can be found in the "Power source" operating instructions or
in the documentation of further peripheral devices.
3 Product Description
3.1 Technical Data
Ambient temperature Welding
- 10 °C to + 40 °C
Transport and storage
- 25 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient conditions for shipment and storage
Type of voltage
DC or AC
DC polarity of the electrodes
Usually negative
Type of use
automatic
Voltage rating
141 V peak value
Max. arc ignition and stabilization voltage
12 kV
Protection type of the machine side connections
IP2X (EN 60 529)
Shielding gas
as per DIN EN 439
Electrode
commercially available tungsten electrodes
suitable for TIG use, preferably low-radiation
Required cooling unit capacity
800 W
Tab. 2
General torch data (EN 60 974-7)
Type
Type of
cooling
Load
ED
Electrode
Gas
flow
Cooling
Torch inlet
pressure
ABITIG
®
MT
DC
AC*
Max. supply
temp.
Min.
flow
min. max.
A
A
%
mm
l/min
°C
l/min
bar bar
260W
liquid
260 180
100 1,0 - 3,2
7 - 20
50
0,7
2,5 3,5
200
air
200 140
60
1,6 - 4,0
7 - 20
Tab. 3
Product-specific torch data (EN 60 974-7)
Summary of Contents for TIG ABITIG MT
Page 4: ...DE 4 1 Identifikation ABITIG MT 1 1 EU Konformit tserkl rung...
Page 21: ...DE 21 ABITIG MT 12 Entsorgung...
Page 24: ...EN 4 1 Identification ABITIG MT 1 1 EU Declaration of Conformity...
Page 41: ...EN 21 ABITIG MT 12 Disposal...
Page 44: ...FR 4 1 Identification ABITIG MT 1 1 D claration de conformit UE...
Page 61: ...FR 21 ABITIG MT 12 Elimination...
Page 64: ...ES 4 1 Identificaci n ABITIG MT 1 1 Declaraci n de conformidad de la UE...
Page 81: ...ES 21 ABITIG MT 12 Eliminaci n...
Page 83: ...ZH 3 ABITIG MT 1 1 WIG WIG WIG WIG ABITIG MT WIG ABICOR BINZEL...
Page 84: ...ZH 4 1 ABITIG MT 1 1...
Page 86: ...ZH 6 2 ABITIG MT 2 3 PPE P3 2 4 2 5...
Page 90: ...ZH 10 6 ABITIG MT 6 6 1 WIG 6 1 1 ABITIG MT200 300W 2 3 3 ZH 7 TRBS 1203 ABITIG MT200 300W x...
Page 92: ...ZH 12 6 ABITIG MT 6 4 6 5 WIG WIG ABICOR BINZEL BTC...
Page 93: ...ZH 13 ABITIG MT 7 1 2 1 2 1 7...
Page 94: ...ZH 14 8 ABITIG MT 7 1 8 9 TRBS 1203 WIG...
Page 95: ...ZH 15 ABITIG MT 9 WIG 1 1 5...
Page 96: ...ZH 16 10 ABITIG MT 9 1 10 11 TRBS 1203 8...
Page 97: ...ZH 17 ABITIG MT 12 WIG 12 11 ZH 16 12 1 12 2 12 3 ABICOR BINZEL TRBS 1203 8 ZH 14...
Page 98: ...ZH 18 12 ABITIG MT...
Page 99: ...ZH 19 ABITIG MT 12...