4 Product description
iCOOL 1200
4 Product description
4.1 Assembly and use
The device is used for cooling liquid-cooled welding torches. The device supplies and monitors the coolant.
All required components and connections have been installed in the housing. The coolant is pumped via
a closed cooling circuit through the welding torch and cooled down via an integrated air heat exchanger.
4.2 Technical data
Fig. 2
Assembly and use
A
Coolant return connector (red)
B
Coolant supply connector (blue)
C
Coolant filler neck
D
Filling level indication
E
Fuse
F
Coolant supply connector (blue), rear
G
Coolant return connector (red), rear
H
Drain coupling
A
B
C
D
F
G
H
E
Tab. 1
Ambient conditions for transport, storage and operation
Ambient temperature
(operation, storage in a closed environment)
−10 °C to +40 °C
Ambient temperature (transport)
−25 °C to +55 °C
Relative humidity
Up to 90% at 20 °C
Tab. 2
General information
Coolant
BTC-20 NF
Max. volume capacity of coolant tank
5 l
Min. required volume capacity of coolant tank
4 l
Max. delivery height of pump head
Max. flow rate of pump head
2.5 l/min.
Power
1.2 kW