6 Commissioning
FEC
6.4 Connector for separate exhaust air hose
1
Loosen the mounting screws
.
2
Dismantle the air exhaust louver
.
3
Connect the exhaust air hose
to the fume extraction system.
6.5 Establishing the electrical connection
13.1 Circuit diagram on page EN-26
1
Mounting screws (4 pieces)
2
Air exhaust louver
3
Exhaust air hose
Fig. 8
Separate exhaust air hose
1
2
3
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed, or worn parts.
NOTICE
• Before an electrical connection between the product and the power supply is established, check that the operating
voltage specified on the nameplate matches the actual voltage.