EN - 8
3 Product description
CAT 3
Load
24 VDC / max. 100 mA
Tab. 4
Micro switch
1
Triggering moment
2
Triggering force X, Y
Fig. 3
Technical data
400
X
Y
Z
2
1
Switching point
Deflection in X and Y direction
Approx. 9-11 mm (Approx. 1.4-1.7°)
1
Deflection in Z direction
Approx. 1.3-1.6 mm
Tab. 5
Triggering the emergency stop switch
1With a distance of 400 mm
In direction
of the X axis and Y axis
7° (45 mm)
Z axis
5.0 mm
Tab. 6
Maximum possible deflection
With pressure spring "M"
32 N
With pressure "L"
44 N
With pressure "XL"
71 N
Tab. 7
Triggering force, 400 mm
Summary of Contents for CAT3
Page 4: ...DE 4 1 Identifikation CAT 3 1 1 EU Konformitätserklärung ...
Page 24: ...EN 4 1 Identification CAT 3 1 1 EU Declaration of Conformity ...
Page 41: ...EN 21 CAT 3 Notes Notes ...
Page 44: ...FR 4 1 Identification CAT 3 1 1 Déclaration de conformité UE ...
Page 63: ...FR 23 CAT 3 Notes Notes ...
Page 66: ...ES 4 1 Identificación CAT 3 1 1 Declaración de conformidad de la UE ...
Page 85: ...ES 23 CAT 3 Notas Notas ...
Page 86: ...ES 24 Notas CAT 3 Notas ...
Page 87: ...ES 25 CAT 3 Notas Notas ...