10 Troubleshooting
ADF 600S
10 Troubleshooting
Please observe the attached ‘Warranty’ document. In the event of any doubts and/or problems, please
contact your retailer or the manufacturer.
DANGER
Risk of injury and machine damage when handled by unauthorised persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the
device. The product warranty will be rendered invalid if work is carried out on it by unauthorised persons.
• Operating, maintenance, cleaning and repair work may only be carried out by qualified personnel (in
Germany see TRBS 1203).
WARNING
Arc eye
Welding with a faulty
ADF 600S
can damage the eyes.
• Immediately stop welding work with the
ADF 600S
and resolve the malfunctions that occurred.
Tab. 11 Troubleshooting on page EN-18
• Only use an intact
ADF 600S
.
NOTICE
• Please also consult the operating instructions for the welding components, such as the power source,
welding torch system, re-circulating cooling unit etc.
Fault
Cause
Troubleshooting
Irregular
darkening.
• The head band was not adjusted evenly.
• Adjust the head band precisely and ensure equal
distance of the eyes to the filter lens.
6.2 Adjusting head band on page EN-10
6.3 Adjusting head circumference on page EN-10
• The distance of the eyes to the filter lens is not
even.
Automatic filter
does not darken
or flickers.
• The viewing pane is dirty or damaged.
• Replace the viewing panes.
6.1 Removing protective film / replacing viewing pane on
page EN-9
• The solar cells / sensors are dirty.
• Clean the surface.
9.1 Cleaning the automatic filter, solar cells, sensors and
helmet shell on page EN-16
• The welding current is too low.
• Set the controller to "higher".
6.5 Adjusting the light sensitivity (SENSITIVITY) on
page EN-14
Slow reaction.
• The operating temperature is too low.
• Observe the recommended operating temperature.
- 5 °C to + 55 °C (23 °F to 131 °F)
Poor view.
• The viewing pane or the automatic filter are dirty
or damaged.
• Replace the viewing pane or the automatic filter.
6.1 Removing protective film / replacing viewing pane on
page EN-9
9.2 Replacing the automatic filter on page EN-17
• The ambient light is insufficient.
• Provide better ambient lighting.
• The protection level is set incorrectly.
• Reset the protection level.
6.4 Protection levels on page EN-13
Tab. 11