BAL.0186 • 2019-06-19
EN - 5
ABITIG
®
Little
3 Product description
3 Product description
3.1 Technical Data
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert and modify the device to enhance its performance without authorization.
• Only qualified personnel are permitted to perform work on the device or system.
Welding
- 10 °C to + 40 °C
Transport and storage
- 10 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient conditions during operation
Type of voltage
DC or AC
DC polarity of the electrodes
Usually negative
Type of use
manual
Voltage rating
113 V peak value
Max. arc ignition and stabilization voltage
Breakdown voltage 50 Hz
8 kV
Protection type of the machine-side connections
(EN 60 529)
IP3X
Shielding gas (DIN EN ISO 14175)
Argon
Electrode
Tungsten electrodes suitable
for TIG use, preferably
low-radiation
Tab. 2
General torch data (EN 60 974-7)
Switching voltage of trigger
0.02 - 42 V (DC and AC)
Switching current of trigger
0.01 - 100 mA
Switching power of trigger
max. 1 W (resistive load)
Tab. 3
Electrical control devices