EN
-
19
ABIROB
®
W
9 Maintenance and cleaning
9.4 Maintenance of the coolant shut-off valve
1
Loosen the clamping screw
2
Dismount valve
3
.
4
Dismount pressure spring
and valve ball
replace it if necessary.
5
for damage and replace them if necessary.
6
Re-insert valve ball
and pressure spring
7
again. In doing so, observe the maximum screw-down
.
8
and secure it with clamping screw
, max. tightening
torque M = 2 Nm.
1
2 valves
2
2 pressure springs
3
2 set screws M8x8
4
2 clamping screws M4x5
5 ABIROB
®
W
cable assembly
6
4 O-rings 7x1
7
max. screw-down depth
8
2 valve balls
Fig. 10
Maintenance of the coolant valve
1
2
4
6
8
5
3
7
Summary of Contents for Abirob W600
Page 23: ...DE 23 ABIROB W 12 Entsorgung ...
Page 45: ...EN 23 ABIROB W 12 Disposal ...
Page 89: ...ES 23 ABIROB W 12 Eliminación ...