EN - 10
7 Maintenance and cleaning
Alignment jig
6.2 Adjusting the bending angle
1
Plug/screw the setting sleeve
onto/into the gas nozzle receptacle.
2
Put the adjusting lever
onto the setting sleeve
and correct the bending angle slightly.
During this process, continually check the concentricity of the test mandrel
.
The bending angle is correct if the test mandrel
fits easily into the bore of the gauging sleeve
.
7 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
7.1 Monthly
Monthly basic cleaning is recommended, and necessary in case of extreme working conditions.
CAUTION
Material damage
Too frequent and excessive bending can destroy the torch neck.
• Only make minor corrections.
1
Test mandrel
2
Gauging sleeve
3
Setting sleeve
4
Adjusting lever
Fig. 5
Adjusting
1
2
3
4
Summary of Contents for ABIROB G360
Page 43: ...1 JA 2 1 ABICOR BINZEL 2 2 1 2 2 TRBS 1203 89 391 2009 104 2004 108 2 3 PPE PPE P3...
Page 44: ...JA 3 3 2 4 4 3 3 1 TRBS 1203 10 C 40 C 20 C 90 1 10 C 40 C 25 C 55 C 20 C 90 2...
Page 45: ...4 JA 4 3 2 3 2 1 3 3 4 www binzel abicor com 4 1 ABIROB G 3 mm 4 1 5 6...
Page 46: ...JA 5 5 4 2 2 JA 3 5...
Page 50: ...JA 9 6 6 2 1 3 2 4 3 1 2 1 2 1 2 3 4 5 1 2 3 4...
Page 51: ...7 JA 10 7 7 1 8 9 10 9 JA 10 10 1 10 2 10 3 ABICOR BINZEL 9 TRBS 1203...