EN - 15
ABIMIG
®
WT
9 Disposal
1
Unscrew the nut of the torch neck.
2
Pull torch neck of the torch neck mount by slightly rotating it.
3
Insert new or serviced torch neck.
4
Tighten the nut by hand.
8.3 Cleaning the torch neck
9 Disposal
NOTICE
• Make sure that no residual coolant enters the wire conduit!
• When unscrewing the torch neck, always keep the torch handle pointing
downwards. This prevents residual coolant from seeping into the gas and
wire guides.
NOTICE
• Grease the O-rings with silicone-free lubricant (192.0078). This makes it
easier to insert the torch neck and increases the life of the O-rings.
NOTICE
• Clean the gas nozzle interior regularly to remove weld spatter and spray
it with original
ABICOR BINZEL
anti-spatter agent.
• Check the wear parts for visible damage and replace defective parts.
• Make sure that the cutting point is clean, in order to increase the life of O-
rings and ensure effective power transmission.
• Replace worn-out or damaged O-rings.
• Use the delivered insulating hose for depositing the torch neck and
protecting the torch neck interface.
NOTICE
• Do not dispose of the device with household waste.
• For disposal, observe the local regulations, laws, provisions, standards
and guidelines.