ABIMIG
®
SpinArc
®
8 Putting out of operation
EN - 13
7
Extend the wire to the required length of the stickout and measure the outer diameter of the wire rotation
using callipers.
After a successful connection, the arc and the rotation of the welding torch are activated using the start
button on the torch guide.
If you do not want rotation to be activated until after the arc has started, use the delay button on the
control device.
8 Putting out of operation
1
Wait until the shielding gas post-flow time has passed.
2
Close the shut-off valve for the gas supply.
3
Switch off the power source.
4
Switch off the control device.
Shaft position
Average rotation diameter in mm
1
0.5 – 1.5
2
1.5 – 2.5
3
2.5 – 3.5
4
3.5 – 4.5
5
4.5 – 5.5
6
5.5 – 6.5
7
6.5 – 7.5
8
7.5 – 8.5
WARNING
Risk of burns
Hot surfaces may cause burns.
• Wait until the torch has cooled down sufficiently before touching it.
NOTICE
• When putting the system out of operation, ensure that the procedures for switching off each of the
welding system components are observed.