![background image](http://html2.mh-extra.com/html/abicor-binzel/ab20/ab20_operating-instructions-manual_3407417010.webp)
EN - 10
6 Maintenance and cleaning
AB Series Torches
NOTE
• When change contact-tip holder or torch neck, or connect Panasonic to
machine side, the contact surface between parts must be clean and free
from hard particles, otherwise the surface will be scraped and good
contact won’t be guaranteed.
• When assemble trigger contact spring onto torch handle, be care not to
bend the spring and make sure the two springs are assembled with the
contact points face to face. The groove on the spring must be set on the
stage shown as the following photo.
1
The contact springs must be assembled with the groove set on the stage of the torch handle
Fig. 2
Assemble trigger contact spring
1