Unit Diagram
Maintenance
**
For more detailed instructions, visit www.unipdry.com**
WARNING: Always unplug the unit before doing any maintenance.
Cleaning the Machine Body
• Use a soft, damp cloth to clean the exterior of unit. Do not use any
soap or solvents
Coil Maintenance
Once per year, clean the coils with an approved coil cleaner. The
coil cleaner should be a self-rinsing,
foaming, cleaner, such as
WEB® Coil Cleaner.
Cleaning the Filter
1. Unplug the unit.
2. For PreFilter:
Pump Maintenance
Your
CTRH
100
is
equipped
with
an
integral
condensate
pump
designed
to
pump
water
from
the
dehumidifier
out
to
the
desired
drain
.
a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).
3. For MERV-10/HEPA/Carbon Filters:
a. Replace as necessary- we
recommend checking the filters
at least 1x/year
Electrical Access
•
• Remove the screw on the
control board cover.
Unscrew the 13 screws on the side panel.
Removing the Pump
1.
2.
3.
4.
Remove
the
9
screws
on
the
side
panel
and
set
panel
aside
.
Remove
the
screw
holding
the
pump
in
place
.
Undo
the
3
pump
electrical
quick
connects
and
1
drain
quick
connect
.
Insert
a
flat
head
screwdriver
into
the
notch
on
the
side
of
the
pump
.
This
will
allow
you
to
gently
lift
the
pump
off
its
reservoir
(
the
reservoir
remains
attached
to
the
unit
).
Preventative
maintenance
is
necessary
to
prevent
issues
from
dirt
and
slime
that
may
accumulate
in
the
drain
system
.
This
includes
the
drain
pan
,
hose
to
the
condensate
pump
,
pump
reservoir
,
pump
head
assembly
,
and
discharge
tubing
.
The
pump
requires
routine
maintenance
that
is
not
covered
by
the
warranty
.
9