ABEM Terrameter SAS 1000 / SAS 4000
- 60 -
For example, if only an ORG-file has been created and no UP- and DWN-files a warning will
be issued. As it is fully legal to define only an ORG-file the compiler accepts this but warns
the user that he/she might have missed to supply the UP- and DWN-files.
8.1.5
Format of Lund Imaging Address, Protocol and Location Files
The measurement process is controlled via address files (.ADR) and protocol files (.ORG,
.UP and .DWN). For measurements involving boreholes location files (.LOC) are also used.
Cable Description Files (Address Files)
The cable description files (address files - extension .ADR) contain information about the
physical configuration of the cables
presently used: number of electrode cables, number
electrode take-outs per section, internal and external addresses of electrode channels, etc. All
parameters are integers.
To edit an existing address file, press the
tool. This brings up the dialog shown below.
The following format is used in the files:
n
sec
n
each
{ number of electrode cables, total number of take-outs per cable }
n
skip
n
x-move
[n
y-move
] { active electrode skip factor, lengths for x-move, lengths for y-move }
n
tot
[n
x
]
{ total no of active take-outs, no of take-outs in x-direction }
1 adr
1
cable
1
-pos
1
{ number, internal address and physical position of 1st take-out }
2 adr
2
cable
2
-pos
2
{ number, internal address and physical position of 2nd take-out }
...
...