ABEM Terrameter SAS 1000 / SAS 4000
- 28 -
Resistance in between electrode and soil
0
200
400
600
800
1000
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
Electrode burial in ground [m]
Re
si
s
ta
n
c
e
[
O
h
m
]
Soil resistivity: 100 Ohm-m
Electrode diameter: 1 cm
5.2
CABLE SETS
The standard Schlumberger and Wenner sounding cable set consists of
2 x 750 m current cable, 0.75 mm
2
, on reel
2 x 250 m potential cable, 0.75 mm
2
, on reel
2 x 2 m connection cable, red
2 x 2 m connection cable, black
4
crocodile clip
The sounding cable set is intended to facilitate Schlumberger and Wenner soundings. The
cables incorporate heavy gauge conductors with excellent insulation to ensure good survey
results. Moreover, there are convenient, short hook-up cables that reduce setup times and
permit you to position the cable drums as desired.
Another important feature of the sounding cable set is easy expandability. If you need to run
longer cables, for deeper penetration, you can purchase additional drums and connect them in
series with your present drums.
Figure 8. Theoretical relation between electrode burial and the contact resistance.