User Configurations
Mode 2: Two Screeners / Switch to Safe Feed
This operational mode accommodates two screeners in series, and the audio inputs/
outputs are embedded in the serial digital video input/output. A violation missed by
Screener 1 can be masked by Screener 2.
At the VIDEO trigger point, the VISUAL violation is masked with a switch to an
undelayed “AUX” safe feed, for the duration the VIDEO Panic Button is held down.
At the AUDIO trigger point, the AURAL violation is masked by a switch to the
“AUX” safe input feed, for the duration the AUDIO Panic Button is held down;
alternatively, the audio can be programmed to “Mute”.
The total delay is dependent on the AirCleaner model and video format. The total
delay in AirCleaner can be divided as desired for the two screeners. A set of Reaction
Time parameters are also available for each screener; one for audio and one for video.
Figure 4-25. Mode 2: Two Screeners / Switch to Safe Feed
Significant Parameters / MAIN Menu:
•
Screeners
= Two
•
Total PGM Delay
= 10:00
(Value is only a suggestion)
•
On Video Trigger = Switch to AUX
•
On Audio Trigger = Switch to AUX
•
Video Reaction 1 = 1:15
(Value is only a suggestion)
•
Audio Reaction 1 = 1:15
(Value is only a suggestion)
•
Video Reaction 2 = 1:15
(Value is only a suggestion)
•
Audio Reaction 2 = 1:15
(Value is only a suggestion)
Significant Parameters / OPTIONS Menu:
•
PGM IN Audio
= Embedded
•
AUX IN Audio
= Embedded
•
Embed. Audio OUT = ON
Summary of Contents for AirCleaner
Page 2: ...ii AirCleaner User Guide ...
Page 10: ...x AirCleaner User Guide Table of Contents ...
Page 54: ...44 AirCleaner User Guide 3 Updating Software Firmware Updating Software Firmware ...
Page 100: ...90 AirCleaner User Guide 4 Operations Control Panel Menu Item Descriptions ...
Page 106: ...96 AirCleaner User Guide Index ...