![background image](http://html1.mh-extra.com/html/abc/ge-8-starguide-iii/ge-8-starguide-iii_quick-start-manual_451093005.webp)
sg3_QS_GE8 03/22/01 Page 5 of 5
NETCUE/DATA CARD
INSTALLATION GUIDE
The NCC contains 16 Form “A” relays to present dry contact closures to the user It also
contains a serial output of ABC DATA. Follow the tables below to wire the NetCue
contact closures and ABC DATA serial output properly:
NETCUES
PIN
Function
PIN
Function
1
RLY0A
20
RLY0B
2
RLY1A
21
RLY1B
3
RLY2A
22
RLY2B
4
RLY3A
23
RLY3B
5
CHASSIS
GND
24
CHASSIS
GND
6
RLY4A
25
RLY4B
7
RLY5A
26
RLY5B
8
RLY6A
27
RLY6B
9
RLY7A
28
RLY7B
10
CHASSIS
GND
29
RLY8B
11
RLY8A
30
RLY9B
12
RLY9A
31
RLY10B
13
RLY10A
32
RLY11B
14
RLY11A
33
NETQ RXD
15
NETQ TXD
34
RLY12B
16
RLY12A
35
RLY13B
17
RLY13A
36
RLY14B
18
RLY14A
37
RLY15B
19
RLY15A
37 PIN RELAY CONNECTOR
IMPORTANT: DO NOT connect your automation device to PINS 5, 10, 15, 24
or 33. PINS 5, 10 and 24 are receiver chassis grounds. PINS 15 and 33 are
serial connections for the NetCue data stream to use with existing ABC
NetCue II boxes. Your relays will not function properly if you wire to these
pins.
PRINTER OR WIRE CAPTURE
RJ-45 SERIAL CONNECTOR
PIN
FUNCTION
PIN
FUNCTION
1
RTS
5
GND
2
6
RXD
3
TXD
7
4
8
CTS
Serial output
: 9600 baud, 8 Data Bits, No Parity, 1 stop-Bit (9600,8,N,1)