Step 6 – Plan Your water Softener system Location

Plan where to position your water softener 

system:

1.  Position 5 ft. from power source to oper

-

ate

2.  Requires water drain for disposing of 

water

3.  Requires access to home’s main water line

Valve to Mineral Tank

Step 7 – Begin Assembly: Fleck Valve to Mineral Tank

1. Apply silicone lube to small inner O-ring.

2.  Attach top basket to the bottom of the Fleck 

5600sxt valve.  Insert large end of basket into groove 

and turn clockwise into locking position.

3.  Apply a thin layer of silicon to large ‘O’-ring locat

-

ed outside of threads.  

4. Connect the Fleck valve to the mineral tank.  Be 

sure to carefully line up the meter’s top basket to the 

mineral tank’s distributor tube.  

The mineral tank’s distributor tube should fit inside 

the top basket.  Once aligned, screw on Fleck meter to 

mineral tank’s threads.  Hand tighten until tank starts 

to spin.  Do not hold tank and over tighten valve.

Summary of Contents for Fleck 5600SXT

Page 1: ...Written by 602abcWATER Fleck 5600SXT Water Softener with Upflow Carbon Tank...

Page 2: ...t our website for installation resources to assist you during your install Phone 602 222 9283 Monday thru Friday 7am to 4pm Arizona time Email support 602abcWATER com Tanks 1 Mineral tank prefilled wi...

Page 3: ...tep 2 Attach bypass valve 1 Lube O rings on the bypass valve and attach bypass valve to the in out head fitting the female ends with the easy tighten nuts onto the female ends of the in out head Hand...

Page 4: ...pair 1 male treaded elbow adapters You will be placing the nut followed by the white slip ring Push the white slip ring down to the in ner most groove Next slide the split ring onto elbow placing in l...

Page 5: ...ch top basket to the bottom of the Fleck 5600sxt valve Insert large end of basket into groove and turn clockwise into locking position 3 Apply a thin layer of silicon to large O ring locat ed outside...

Page 6: ...Tank The Resins in the tank are used to replace the magnesium and calcium ions found in hard water with sodium ions and discharges from the Downflow Inlet Waste water flows out of the Drain Barb BR S...

Page 7: ...Fleck 5600sxt head The Brine Tank uses common salt to create this brine solution In normal operation hard water moves into the mineral tank and the calcium and magnesium ions move to the beads replac...

Page 8: ...use the connection is O ring sealed it s important not to overtighten the screw Overtightening will cause damage to the plastic assembly Meter Valve Assembly Step 5 Connect Yoke to Bypass 1 Apply sili...

Page 9: ...to dispose of waste water Attach Tank Lines Step 7 Connect Brine Line to Fleck Meter 1 Prep brine line prior to install using brass nut plastic Ferrule brass tube insert 2 Connect provided brass nut t...

Page 10: ...o the home s incoming water line Step 11 Connect Meter to Power Source 1 Plug in the Fleck 5600sxt digital meter to a power receptacle Your power source should be less than 5 feet in distance from the...

Page 11: ...DO We suggest 14 days Press Cycle button icon of arrows in diamond pattern after days are set Step 4 Set Regeneration Time RT We suggest setting to 2 00am This is the time that the system will regener...

Page 12: ...Technical sup port is available Monday thru Friday between the hours of 7am to 4pm AZ time 23910 N 19th Ave Ste 8 Phoenix Arizona 85085 Web www 602abcWATER com Phone 602 222 9283 Email support 602abcW...