Summary of Contents for 4T2 bmp 3000

Page 1: ...eb www 4T2 eu 2019 Advanced Broadcast Components All Rights Reserved Copyright in the whole or any part of this document belongs to ABC and may not be used sold transferred copied or reproduced in whole or in part in any manner or form or in or on any media to any person without the prior written consent of ABC 4T2 BroadcastMultiProbe bmp3000 ManualEN odt Page 1 ...

Page 2: ...on remarks 6 2 PRODUCT OVERVIEW 7 3 GETTING STARTED 8 3 1 Start up procedure 8 4 RIGHT HAND SIDE CONNECTORS AND FEATURES 8 5 LEFT HAND SIDE CONNECTORS AND FEATURES 9 6 TECHNICAL SPECIFICATIONS 10 7 MISCELLANEOUS 14 7 1 Declaration of Conformity 14 7 2 Maintenance and calibration 15 7 3 Dimensions and shipping information 15 7 4 Application notes 15 7 5 Waiver 15 4T2 BroadcastMultiProbe bmp3000 Man...

Page 3: ... not recommended to drop or throw the 4T2 It should also be avoided to expose the instrument to high humidity or water in it s liquid form Shall you plan to store the 4T2 in that kind of conditions ABC recommends to do so in the supplied carrying case 1 2 Which instruments are covered by this manual This manual covers all 4T2 Portable Broadcast Multi Probe instruments ABC takes great care that any...

Page 4: ...vanced Broadcast Components recommends saving your box and its packing materials Original packaging is preferred for shipment or relocation of your device Substitute packaging may not provide adequate protection 1 4 Environmental aspects The device has been designed under aspects of environmental friendliness The packaging has been optimised in terms of recycling possibilities transport safety and...

Page 5: ...one mentioned in the manuals will be treated as not agreed All relevant safety and accident prevention instructions have to be observed during commissioning operation and maintenance All safety regulations and accident prevention instructions according to the specific operation scenario have to be observed Opening of the 4T2 Broadcast Multi Probe is not allowed and voids the warranty Regular check...

Page 6: ...erwise altered under any circumstances as this may influence the overall performance Installation of not approved third party hardware may damage the 4T2 and is not being covered under the 4T2 warranty We recommend to consult ABC if in doubt of compatibilities of hardware Opening of the 4T2 voids the warranty There are no user serviceable parts inside the 4T2 The 4T2 BIOS is usually password prote...

Page 7: ...rement of PCR Program Clock Reference jitter Content decoding of SD HD UHD material with Monitor wall feature with audio bar graphs Detection of black and freeze and audio mute conditions on services in the TS Triggered capture of Transport Stream to disk in presence of errors with history Remote capability with full SNMP support following the DVB MIB including Traps Input support for files Compre...

Page 8: ... interface is powered from the table computer directly Please note that once powered on a blue light appears next to the power input connector If the light stays off then the battery of the 4T2 bmp is likely to be empty The magnetic touch keyboard is used to protect the TFT display in transport mode 4 Right hand side connectors and features On the right hand side you will find connectors essential...

Page 9: ... Jack headphone output of tablet computer Volume up down rocker switch CI Dual Common Interface slot ASI Asynchronous Serial Interface MPEG Transport Stream input CPL Coupler output from tracking generator TG Tracking Generator main output RF Radio Frequency main input 4T2 BroadcastMultiProbe bmp3000 ManualEN odt Page 9 ...

Page 10: ...2 demodulator QPSK 8PSK 16APSK 32APSK Symbol Rate 0 2 45 Msps Carrier Capture Range 10 MHz DVB S2 QPSK Puncture codes 1 2 3 5 2 3 3 4 4 5 5 6 8 9 9 10 DVB S2 8PSK Puncture codes 3 5 2 3 3 4 5 6 8 9 9 10 DVB S2 16PSK Puncture codes 2 3 3 4 4 5 5 6 8 9 9 10 DVB S2 32PSK Puncture codes 3 4 4 5 5 6 8 9 9 10 Measurement Results Resolution Accuracy Input level 0 1 dBm 2 dB Transport Stream Input output ...

Page 11: ... s look up table Bitrate Offset 0 1 bit s t b d Cell Identifier COFDM Demodulation DVB T2 1 3 1 Modulation QPSK 16 QAM 64 QAM 256 QAM rotated non rotated FFT length 1k 2k 4k 8k 16k 32k ext BW Code rates 1 2 3 5 2 3 3 4 4 5 5 6 Guard interval factor 1 4 19 128 1 8 19 256 1 16 1 32 1 128 Reed Solomon 188 204 byte packets Mode detection Automatic Synchronisation time 5 s Measurement Results Resolutio...

Page 12: ... Residual FM 3KHz Audio LPF 15 KHz IF BW 0 1 Hz 4 Hz GHz typical RMS FM e g 2 GHz RF would have 8 1 Hz RMS FM Increasing IF BW increases residual FM Amplitude Range 1dB Gain Compression 1dB Gain Compression to Displayed Average Noise Level DANL attenuator set to 15dB preamp off 16dBm Typical 1Hz to 150MHz 100 kHz to 150 MHz Option 3 19dBm Typical 150MHz to 4 4GHz Absolute Accuracy Reference level ...

Page 13: ... x 280 x 100 mm Weight 4 5 kg Power Supply 12V DC Operating Temperature 0 C 40 C Storage Temperature 20 C 50 C Relative Humidity 5 85 non condensing Shock 3 g max Standards Qualifications DVB T DVB T2 compliance EN 300 744 EN 302 755 TS 101 190 TS 101 191 TS 102 773 Measurement Guidelines TR 101 290 MPEG Compliance ISO IEC 13818 1 ITU T H 222 0 EMC DIN EN 55022 2001 09 DIN EN 55024 2002 11 DIN EN ...

Page 14: ...be Model Number 10 110 300 Trademark 4T2 is in conformity with the essential requirements of the R TTE Directive 1999 5 EC The above mentioned product is in compliance with the following European standards Electrical Safety EN 60950 1 2001 EMC ETSI EN 55022 2001 09 ETSI EN 55024 2001 11 ETSI EN 55013 2003 10 partly ETSI EN 61000 3 2 2001 12 Low Voltage Directive 73 23 EWG Bad Segeberg Germany 01 0...

Page 15: ...or application notes is the internet Printed copies can be ordered directly from ABC 7 5 Waiver While the information contained in this document has been carefully compiled to the best of our present knowledge it is not intended as representation or warranty of any kind on our part regarding the suitability of the products concerned for any particular use or purpose and neither shall any statement...