![ABB ZSD 2020 Overhaul Instructions Download Page 23](http://html.mh-extra.com/html/abb/zsd-2020/zsd-2020_overhaul-instructions_3045399023.webp)
Date: 2021-01-13
Version: 1.2
Overhaul instructions
Central lubrication unit
Removing
Page 23 of 50
•
Pull the oil filter off the filter head.
Figure 9: Removing the oil filter
DANGER
Danger through electric current!
Risk of serious or fatal injury through incorrect handling.
Only qualified electricians must operate or work on the electrical installation. The
plant must be isolated from mains power and secured against restarting during this
work. Observe all information about machine parts that remain live when the plant
is switched off at the main switch.
© 2021 ABB Automation GmbH |
en