8.3.4
Setting of the door opener or light switch
The setting is only made on the door/light switch actuator. It shows the respective function of the device in the
ABB-Welcome
®
system. The sliding switch on the device is used for setting.
8.3.5
Setting of the door opener times and light times
This setting on the system controller and the door/light switch actuator determines the operating period of the
door buzzer (from one to ten seconds). The light-on period can be set between one second and five minutes. A
separate potentiometer for both is located on the system controller. For the MDRC switch actuator and on the
flush-mounted switch actuator the same potentiometer is used for one of the two control values depending on the
position of the sliding switch.