WaterMaster specification to OIML R49 Class 1
0.1 (0.44)
1.0 (4.4)
10 (44)
100 (440)
1000 (4402)
Err
or (%)
Flowrate m
3
/h (GPM)
Typical meter
performance
±0.2 % ±0.9 mm/s
whichever is the greater
Around Q2 the
performance is
±0.7 mm/s
WaterMaster Class 1
specification
OIML R49 Class 1
accuracy limits
DN100 (4 in. NB)
WaterMaster specification to OIML R49 Class 2
0.1 (0.44)
1.0 (4.4)
10 (44)
100 (440)
1000 (4402)
Err
or (%)
Typical meter
performance
±0.4 % ±0.9 mm/s
whichever is the greater
Around Q2 the
performance is
±0.7 mm/s
WaterMaster Class 2
specification
OIML R49 Class 2
accuracy limits
DN100 (4 in. NB)
Flowrate m
3
/h (GPM)
Although OIML R49 does not define the flow accuracy below Q1, WaterMaster continues to measure flow at lower flow rates