… Electromagnetic flowmeter WaterMaster FEF12 and FEF18
Product coding field number 1 … 5 6 7 … 9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27
Opt
ions
Flowmeter system, full bore, remote mount
FEF12
X XXX X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
Full bore sensor only,
for use with WaterMaster transmitter / remote
FEF18
Temperature range installation / ambient temperature range
Standard design / –20 to 60 °C (–4 to 140 °F)
1
Nameplate
Adhesive
A
Signal cable length and type*
Without signal cable
5 m (15 ft.) cable
10 m (30 ft.) cable
20 m (60 ft.) cable
30 m (100 ft.) cable
50 m (165 ft.) cable
80 m (260 ft.) cable
100 m (325 ft.) cable
150 m (490 ft.) cable
Special Length > 150 m (> 490 ft.) (and / or armored cable)
0
1
2
3
4
5
6
7
8
9
Explosion protection certification
General purpose (non-Ex design)
A
Protection class transmitter / protection class sensor
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted
IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted
2
3
Cable conduits**
M20 x 1.5 (plastic)
NPT 1/2 in. (blanked when cable not fitted)
M20 SWA (armored)
M20 SWA sensor, M20 x 1.5 (plastic) power / output
Without
A
B
D
F
Y
Power supply
Without
100 to 230 V AC (50 Hz)
24 V AC or 24 V DC (50 Hz)
100 to 230 V AC (60 Hz)
24 V AC or 24 V DC (60 Hz)
0
1
2
3
4
Input and output signal type
HART + 20 mA + pulse + contact output
PROFIBUS DP RS485 physical layer + pulse + contact output
MODBUS RTU RS485 physical layer + pulse + contact output
Without
A
G
M
Y
Configuration type / diagnostics type
Without
Factory defaults / standard diagnostics
0
1
Options**
Accessories
Configuration lead
AC
Documentation language
German
Italian
Spanish
French
English
M1
M2
M3
M4
M5 (default)
Chinese
Swedish
Finnish
Portuguese
Danish
Norwegian
M6
M7
M8
MA
MF
MN
Verification type
Without
fingerprint
VeriMaster
V0
V3
Potable water approvals
WRAS cold water approval
NSF 61 meter approval
DVGW
ACS
WRAS 60 °C (140 °F) water approval
Without
CWA
CWC
CWD
CWF
CWK
CWY
Power supply frequency (sensor FEF 18 only)
50 Hz
60 Hz
F5
F6
Number of testpoints
1 Point
3 Points
T1
T3
*The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered – for FM or FMC
Approved versions, NPT only permitted.