![ABB UNO-DM-3.3-TL-PLUS Product Manual Download Page 27](http://html1.mh-extra.com/html/abb/uno-dm-3-3-tl-plus/uno-dm-3-3-tl-plus_product-manual_3698585027.webp)
- 27 -
000680AG
2 - Characteristics
T
ightening torques
To maintain the IP65 protection of the system and for optimal installation,
the following tightening torques must be used:
AC output connector cable gland
10
(ring nut fastening)
4...5 Nm
Screws for securing AC output connector cables gland
0.8...1 Nm
Service cable gland
20
M25 (ring nut fastening)
5.0 Nm
Service cable gland
20
M25 (lock nut fastening)
7.5 Nm
Front cover fastening screws
05
2.5 Nm
Screw for external ground connection
19
2.5 Nm
O
verall dimensions
The overall dimensions are expressed in millimetres and inches and in-
clude the wall installation bracket.
418mm - 16.45”
175
mm
6.89
”
553mm - 21.77”