14
TZIDC
DIGITAL POSITIONER | DS/TZIDC-EN REV. G
—
… Specification
Communication
•
HART protocol 5.9 (standard); optionally HART®7.4
• Local connector for LCI adapter
(not in explosion protection area)
• HART communication via 4 to 20 mA signal line with HART
compatible modem.
Environmental conditions
Ambient temperature range
During operation, storage, and
transport
−
40 to
85
°C
(−40
to
185
°F)
Limit monitor with proximity switches
SJ2-SN
−25
to
85 °C (−13
to
185
°F)
TZIDC remote sensor
−
40 to
100
°C
(−40
to
212
°F)
* Increased temperature range only with TZIDC Remote Sensor.
Relative humidity
During operation with housing closed
and air supply switched on
95
% (annual average),
condensation permissible
Transport and storage
75
% (annual average)
Safety Integrity Level
Applies to applications with single-acting and depressurizing
pneumatics.
The positioner meets the following requirements:
•
functional safety in accordance with IEC 61508
•
Explosion protection (depending on the version)
• Electromagnetic compatibility in accordance with EN
61000
Without the input signal, the pneumatic module in the
positioner vents the actuator and the spring installed in it
moves the valve to a predetermined end position (OPEN or
CLOSED).
SIL specific safety-related characteristics:
Product
SSF
PFDav
λdd + λs
λdu
TZIDC with supply current
0 mA
94 %
1.76 * 10
-4
651 FIT
40 FIT
For details refer to the Management Summary in the SIL
Safety Instructions 37/18
-
79XA.
Summary of Contents for TZIDC
Page 1: ...ABB MEASUREMENT ANALYTICS DATA SHEET TZIDC Digital positioner...
Page 35: ...TZIDC DIGITAL POSITIONER DS TZIDC EN REV G 35 FM installation drawing No 901265 Page 1 of 5...
Page 37: ...TZIDC DIGITAL POSITIONER DS TZIDC EN REV G 37 Page 3 of 5...
Page 39: ...TZIDC DIGITAL POSITIONER DS TZIDC EN REV G 39 Page 5 of 5...