![ABB TTF200 Operating Instructions Manual Download Page 6](http://html.mh-extra.com/html/abb/ttf200/ttf200_operating-instructions-manual_4530006.webp)
6
TTF200
FIELD-MOUNT TEMPERATURE TRANSMITTER | OI/TTF200-EN REV. B
… 2 Use in potentially explosive atmospheres in accordance with
ATEX and IECEx
Temperature data
Transmitter
ATEX / IECEx intrinsic safety
Temperature class
Permissible ambient temperature range
Device category 1 use Device category 2 / 3 use
T6
−
40 to 44 °C
(
−
40 to 111.2 °F)
−
40 to 56 °C
(
−
40 to 132.8 °F)
T4-T1
−
40 to 60 °C
(
−
40 to 140.0 °F)
−
40 to 85 °C
(
−
40 to 185.0 °F)
ATEX / IECEx Flameproof (Enclosure)
Temperature class
Permissible ambient temperature range on the
connection head
T6
−
40 to 67 °C (
−
40 to 152 °F)
T4 to T1
−
40 to 85 °C (
−
40 to 185 °F)
LCD indicator
ATEX / IECEx intrinsic safety
Temperature class
Permissible ambient temperature range
Device category 1 use Device category 2 / 3 use
T6
−
40 to 44 °C
(
−
40 to 111.2 °F)
−
40 to 56 °C
(
−
40 to 132.8 °F)
T4-T1
−
40 to 60 °C
(
−
40 to 140 °F)
−
40 to 85 °C
(
−
40 to 185 °F)
Electrical data
Transmitter
Intrinsic safety type of protection Ex ia IIC (Part 1)
Supply circuit
Max. voltage
U
i
= 30 V
Short-circuit current
I
i
= 130 mA
Max. power
P
i
= 0.8 W
Internal inductance
L
i
= 160 µH
Internal capacitance
C
i
= 0.57 nF
Intrinsic safety type of protection Ex ia IIC (Part 2)
Measurement current circuit
Resistance
thermometers,
resistors
Thermocouples, voltages
Max. voltage
U
o
= 6.5 V
U
o
= 1.2 V
Short-circuit current
I
o
= 17.8 mA
I
o
= 50 mA
Max. power
P
o
= 29 mW
P
o
= 60 mW
Internal inductance
L
i
= 0 mH
L
i
= 0 mH
Internal capacitance
C
i
= 118 nF
C
i
= 118 nF
Maximum permissible
external inductance
L
o
= 5 mH
L
o
= 5 mH
Maximum permissible
external capacitance
C
o
= 1.55
μ
F
C
o
= 1.05
μ
F
Intrinsic safety type of protection Ex ia IIC (Part 3)
LCD indicator interface
Max. voltage
U
o
= 6.2 V
Short-circuit current
I
o
= 65.2 mA
Max. power
P
o
= 101 mW
Internal inductance
L
i
= 0 mH
Internal capacitance
C
i
= 0 nF
Maximum permissible
external inductance
L
o
= 5 mH
Maximum permissible
external capacitance
C
o
= 1.4
μ