u
Check that nuts (90458) on three safety segments have been
tightened.
u
Fasten lifting device (90190) complete with shackle (90195) to front
side of flange (
F
).
u
Fit O-ring (76040).
u
Remove support angle. (90025)
u
Fit four guide studs (90320).
u
Carefully put compressor casing internal part complete with wall in-
sert and diffuser over guide studs.
u
Remove the guide studs (90320) and fit the studs (74026/74029).
If provided
u
Use studs [10x 74029 and 2x 74026 (each screwed in at top and bot-
tom)].