Read and understand this document 

Please read and understand this document before using the products. Please consult your ABB/JOKAB SAFETY 
representative if you have any questions or comments. 

WARRANTY 

ABB/JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship 
for a period of one year (or other period if specified) from date of sale by ABB/JOKAB SAFETY.  

ABB/JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, 
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED 
USE. ABB/JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. 

LIMITATIONS OF LIABILITY 

ABB/JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL 
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  

In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on 
which liability asserted.  

IN NO EVENT SHALL ABB/JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER 
CLAIMS REGARDING THE PRODUCTS UNLESS ABB/JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE 
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

SUITABILITY FOR USE 

ABB/JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply 
to the combination of products in the customer’s application or use of the product. At the customer’s request, 
ABB/JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of 
use that apply to the products. This information by itself is not sufficient for a complete determination of the 
suitability of the products in combination with the end product, machine, system, or other application or use.  

The following are some examples of applications for which particular attention must be given. This is not intended 
to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be 
suitable for the products:  

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not 
described in this document.  

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, 
amusement machines, vehicles, and installations subject to separate industry or government regulations.  

Systems, machines, and equipment that could present a risk to life or property.  

Please know and observe all prohibitions of use applicable to the products.  

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE ABB/JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE 
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

PERFORMANCE DATA 

While every effort has been taken to ensure the accuracy of the information contained in this manual ABB/JOKAB 
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and 
improvements without notice. Performance data given in this document is provided as a guide for the user in 
determining suitability and does not constitute a warranty. It may represent the result of ABB/JOKAB SAFETY’S 
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to 
the ABB/JOKAB SAFETY Warranty and Limitations of Liability. 

Summary of Contents for Tina 3A/Aps

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 3A Aps Adaptor unit ...

Page 2: ...AFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attenti...

Page 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 9 Installation precautions 9 Maintenance 9 Testing of the safety functions 9 Troubleshooting 9 5 Operation 10 LED indication 10 Information output signal attributes 10 6 Technical data 11 Dimensions 12 7 EC Declaration of conformity 13 ...

Page 4: ...r of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipmen...

Page 5: ...quipped with two additional connection cables for external power supply The Tina3A Aps adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and reduce the risk of electrical interference the unit must be installed within the same physical encapsulation as the safety device The connection cables should be as short as...

Page 6: ...ot monitored and must therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level fault exclusion refer to EN ISO 13849 2 2003 Annex D The safety loops shall not be used for purposes other than intended All loading or tampering with loops can lead to serious risk of life 5 pole M12 connector 1 Brown 24 VDC 2 White Dynamic signal input 3 Blue ...

Page 7: ...2TLC172125M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Tina 3A Caution All cable colours according to ABB Jokab Safety standard cables ...

Page 8: ...2TLC172125M0201 rev A 8 www abb com lowvoltage 2011 09 20 Tina 3Aps Caution All cable colours according to ABB Jokab Safety standard cables ...

Page 9: ...s unit The LED should flash between green and red Interrupt protection The LED should light red The LED should light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of faults Checking and measures to take Lights red Sensor pushed opened Check status of the sensor Bad connection between loops green and or ora...

Page 10: ...l is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signal No dynamic signal 24 VDC 0 VDC Info output signal pin 5 High High Low High The delay for switching the information signal output fro...

Page 11: ...tage Dynamic input between 9 and 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connectors M12 5 pole connector Green loop wires A1 A2 Orange loop wires B1 B2 Brown 24 VDC Blue 0 VDC wires Tina 3Aps only Size ...

Page 12: ...2TLC172125M0201 rev A 12 www abb com lowvoltage 2011 09 20 Dimensions Tina 3A Tina 3Aps NB All measurements in millimetres ...

Page 13: ...d to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including lo...