background image

 

 

2TLC172121M0201, rev. A 

10 

www.abb.com/lowvoltage 

2011-09-20  

6  Technical data 

Manufacturer 

Address 

ABB AB / JOKAB SAFETY 
Varlabergsvägen 11 
SE-434 39 Kungsbacka 
Sweden 

Article number/Ordering data 

Tina 2A: 2TLA020054R0100 
Tina 2B: 2TLA020054R1100 

 

Power supply 

Operating voltage 

24 VDC +15 %, -25 % 

Total current consumption 

17 mA (27 mA with max information output) 
Information output: Max 10 mA 

Time delay t (in/out) 

t < 60 µs 

Voltage supply at normal operation (protection 
OK) and 24 VDC supply voltage 

Dynamic input: between 9 and 13 volt (RMS) 
Dynamic output: between 9 and 13 volt (RMS) 
Information output: ~ 23 VDC 

 

General 

Protection class 

IP67 

Ambient temperature 

Storage: -30…+70°C 
Operation: -10…+55°C 

Humidity range 

35 to 85 % (with no icing or condensation) 

Housing material 

PVC 

Connector 

5x 0.34 mm

2

 wires, 0.15 m 

Size 

Tina 2A: 46 x 27 x 24 mm  
Tina 2B: 26 x 21 x 7 mm (L x W x H) 

Weight 

Tina 2A: ~30 g  
Tina 2B: ~20 g 

Colour 

Black 

 

Safety / Harmonized Standards 

Conformity 

European Machinery Directive 2006/42/EC 

 

EN ISO 12100-1:2003, EN ISO 12100-2:2003, 
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008, 
EN 62061:2005 

IEC/EN 61508-1…7 

SIL3, PFHd: 4.50*10

-9

 

EN 62061 

SIL3 

EN ISO 13849-1 

Performance level: Pl e, category 4 

EN 954-1 

Category 4 

Certificates 

TÜV Nord 

Summary of Contents for Tina 2B

Page 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com lowvoltage Original instructions Tina 2A B Adaptor unit...

Page 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete deter...

Page 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troub...

Page 4: ...of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warn...

Page 5: ...ty sensors without an M20 threaded connector The Tina2A B adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and re...

Page 6: ...used for the safety purpose s The connection cables are not monitored and must therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level faul...

Page 7: ...2TLC172121M0201 rev A 7 www abb com lowvoltage 2011 09 20 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables...

Page 8: ...ions Make sure the safety unit is working properly by following these steps Interrupt the dynamic safety circuit before this unit The LED should flash between green and red Interrupt protection The LE...

Page 9: ...namic signal Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The...

Page 10: ...d 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no ici...

Page 11: ...2TLC172121M0201 rev A 11 www abb com lowvoltage 2011 09 20 Dimensions Tina 2A Tina 2B NB All measurements in millimetres...

Page 12: ...to compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 2...

Reviews: