background image

 

 

2TLC172119M0201, rev. A 

www.jokabsafety.com 

2011-09-20  

1  Introduction 

Scope 

The purpose of these instructions is to describe the adaptor units Tina 2A/B and to provide the necessary 
information required for installation and operation. 

Audience 

This document is intended for authorized installation personnel. 

Prerequisites 

It is assumed that the reader of this document has knowledge of the following: 

  Basic knowledge of ABB/Jokab Safety products. 

  Knowledge of machine safety. 

Special notes 

Pay attention to the following special notes in the document: 

 Warning!

 

Danger of severe personal injury! 
An instruction or procedure which, if not carried out correctly, may result in injury to the technician 
or other personnel. 

Caution!

 

Danger of damage to the equipment! 
An instruction or procedure which, if not carried out correctly, may damage the equipment. 

NB:  Notes are used to provide important or explanatory information. 

 

Summary of Contents for Tina 2A

Page 1: ...ABB AB Jokab Safety Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com Original instructions Tina 2A B Adaptor unit ...

Page 2: ...FETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attentio...

Page 3: ...iew 5 General description 5 Safety regulations 5 3 Connections 6 Connection examples 7 4 Installation and maintenance 8 Installation precautions 8 Maintenance 8 Testing of the safety functions 8 Troubleshooting 8 5 Operation 9 LED indication 9 Information output signal attributes 9 6 Technical data 10 Dimensions 11 7 EC Declaration of conformity 12 ...

Page 4: ...of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of machine safety Special notes Pay attention to the following special notes in the document Warning Danger of severe personal injury An instruction or procedure which if not carried out correctly may result in injury to the technician or other personnel Caution Danger of damage to the equipment ...

Page 5: ...ty sensors without an M20 threaded connector The Tina2A B adaptor unit is intended for use in safety circuits in accordance with EN 60204 1 Warning In order to maintain the highest safety level and reduce the risk of electrical interference the unit must be installed within the same physical encapsulation as the safety device The connection cable should be as short as possible max 150 mm Safety re...

Page 6: ... used for the safety purpose s The connection cables are not monitored and must therefore be installed within the same physical enclosure as the safety device to maintain the highest safety level fault exclusion refer to EN ISO 13849 2 2003 Annex D The safety adaptor shall not be used for purposes other than intended All loading or tampering with the device can lead to serious risk of life 5 pole ...

Page 7: ...rev A 7 www jokabsafety com 2011 09 20 Connection examples Caution All cable colours according to ABB Jokab Safety standard cables More connection examples can be found at www jokabsafety com or in the Safety Handbook ...

Page 8: ...ons Make sure the safety unit is working properly by following these steps Interrupt the dynamic safety circuit before this unit The LED should flash between green and red Interrupt protection The LED should flash between green and red The LED will light green when protection is OK and if the safety circuit s before this unit is not interrupted Troubleshooting LED indication Expected causes of fau...

Page 9: ...namic signal Dynamic signal input does not exist i e the safety circuit is interrupted before this unit 24 VDC A constant 24 VDC signal is applied high H 0 VDC The pin is connected to 0 VDC low L The information output signal depends on the input signal according to the table below Note that if the safety is interrupted the information output signal is always low L Input signal pin 2 Dynamic signa...

Page 10: ...d 13 volt RMS Dynamic output between 9 and 13 volt RMS Information output 23 VDC General Protection class IP67 Ambient temperature Storage 30 70 C Operation 10 55 C Humidity range 35 to 85 with no icing or condensation Housing material PVC Connector 5x 0 34 mm 2 wires 0 15 m Size Tina 2A 46 x 27 x 24 mm Tina 2B 26 x 21 x 7 mm L x W x H Weight Tina 2A 30 g Tina 2B 20 g Colour Black Safety Harmonize...

Page 11: ...2TLC172119M0201 rev A 11 www jokabsafety com 2011 09 20 Dimensions Tina 2A Tina 2B NB All measurements in millimetres ...

Page 12: ...o compile the technical file Lars Magnus Felth ABB AB JOKAB SAFETY Varlabergsvägen 11 SE 434 39 Kungsbacka Sweden Product Certificate Serialnumber Non contact safety sensor Eden Adam Eva E C EC 44 207 10 372092 001 000 000 999 999 Adapter unit Tina 1 8 Tina 10 12 44 207 10 372092 001 000 000 999 999 Muting unit FMC Tina 44 207 10 372092 001 000 000 999 999 Non contact safety sensor including locki...

Reviews: