8
Technical Data
8.1
Electrical data
AC Input
AC input voltage range
(1)
208 - 240 V
AC
+/- 10% (60Hz)
(2)
480 V
AC
+/- 10% (60Hz)
AC input power connection
(1)
1-phase, 208-240 V
AC
: L1, L2, GND
(2)
3-phase, 480Y/277 V
AC
: L1, L2, L3, N,
GND
Maximum rated input current at nominal voltage
(1)
100 A
(2)
32 A
Recommended upstream overcurrent protection
device rating
(1)
125 A
(2)
40 A
Power factor
> 0.96
Efficiency
94% at nominal output power
DC output
Maximum DC output power
(1)
19.5 kW @ 208 V
(1)
22.5 kW @240 V
(2)
24 kW peak; 22.5 kW continuous
DC output voltage range
CCS1: 150 - 920 VDC
CHAdeMO: 150 – 500 VDC
Maximum DC output current
60 ADC
(1)
Single phase configuration
(2)
Three phase configuration
General
DC connection standard
EN61851-23 / DIN 70121 CCS 2 CHAdeMO 1.0
DC cable length
3.5 meters or 7 meters (12 feet or 23 feet)
DC plug type
CCS 1 / CHAdeMO
RFID data
ISO/IEC14443A/B, ISO/IEC15693, NFC reader
mode, Mifare, Calypso
RFID system
FeliCa™1, NFC reader mode
Network connection
GSM / 4G modem
10/100 Base-T Ethernet