background image

Parameter

Specification
FCC Part 15 Class B

ENERGY STAR

Power consumption

CE model

MID model

UL model

UL model with display

In stand-by mode:

4 W

4.6 W

3.6 W (ENERGY STAR compliant)

4.6 W

7.3

Meter specifications for a MID certified EVSE (IEC

portfolio)

Parameter in 2014/32/EU directive

Specification

Mechanical environment

M1

Shock and vibrations of low significance

Electromagnetic environment

E2

7.4

Ambient conditions

Parameter

Specification

Operation temperature

-35°C

2

 to +50°C

Operation temperature for MID certified

models

-30°C to +55C

Storage temperature

-40°C to +80°C

Storage conditions

Indoor, dry

Relative humidity

<95%, non-condensing

7.5

Noise level

Parameter

Specification

Noise level

Less than 35 dB(A)

2

Based on manufacturer test results

Technical data

BCM.V3Y00.0-EN | 002

49

Summary of Contents for Terra AC

Page 1: ...User manual Terra AC Copyright ABB All rights reserved ...

Page 2: ...Copyright All rights to copyrights registered trademarks and trademarks reside with their respective owners Copyright ABB EV Infrastructure All rights reserved 2 BCM V3Y00 0 EN 002 ...

Page 3: ...rtfolio 11 2 4 Product label UL portfolio 12 2 5 Overview 13 2 5 1 Overview of the system 13 2 5 2 Overview of the EVSE outside 13 2 5 3 Overview of the EVSE inside CE model 15 2 5 4 Overview of the EVSE inside MID model 16 2 5 5 Overview of the EVSE inside UL model 17 2 5 6 Overview of the EVSE inside UL model with display 18 2 6 Options 19 2 6 1 Display 19 2 6 2 EV charge cable Type 2 19 2 6 3 S...

Page 4: ...ning or maintenance 31 3 9 Signs on the EVSE 32 3 10 Discard the EVSE or parts of the EVSE 32 3 11 Special safety instructions UL portfolio 33 3 11 1 Important safety instructions UL portfolio 33 4 Operation 34 4 1 Prepare before use 34 4 2 Energize the EVSE 34 4 3 Connect the EVSE with the ChargerSync app 34 4 4 Start a charge session 35 4 4 1 EVSE with an EV charge cable 35 4 4 2 EVSE with a soc...

Page 5: ... 7 4 Ambient conditions 49 7 5 Noise level 49 7 6 Dimensions 50 7 6 1 AC input with socket cable Type 2 50 7 6 2 AC input with EV charge cable 51 7 6 3 Space requirements for installation 51 7 7 AC input specifications 52 7 7 1 General specifications 52 7 7 2 AC input specifications IEC portfolio 52 7 7 3 AC input specifications UL portfolio 53 7 8 AC output specifications 53 7 8 1 AC output speci...

Page 6: ...ent are in English EN US All other language versions are translations of the original instructions 1 5 Illustrations It is not always possible to show the configuration of your EVSE The illustrations in this document show a typical setup They are for instruction and description only 1 6 Units of measurement SI units of measurement metric system are used If necessary the document shows other units ...

Page 7: ... you do not obey the instruction this can cause damage to the EVSE or to property Note A note gives more data to make it easier to do the steps for example Information about the condition of the EVSE before you start the procedure Requirements for personnel for a proce dure General safety instructions for a proce dure Information about spare parts that are necessary for a procedure Information abo...

Page 8: ... risk of electrocution Risk of pinching or crushing of body parts Rotating parts that can cause a risk of entrapment Note It is possible that not all symbols are present in this document 1 11 Related documents Document name Target group Product data sheet All target groups Installation manual Qualified installation engineer User manual Owner Declaration of conformity CE All target groups You can f...

Page 9: ...supply equipment MID Measuring Instruments Directive NFC Near field communication NoBo Notified body OCPP Open charge point protocol PE Protective earth PPE Personal protective equipment RFID Radio frequency identification Note It is possible that not all abbreviations are present in this document 1 14 Terminology Term Definition Network operating center of the manufacturer Facility of the manufac...

Page 10: ... owner of the EVSE Site operator Entity that is responsible for the day to day control of the EVSE The site operator does not have to be the owner User Owner of an EV who uses the EVSE to charge the EV Note It is possible that not all terms are present in this document 1 15 Orientation agreements D C B X Z Y A A Front side face forward to the EVSE during normal use B Left side C Right side D Rear ...

Page 11: ...essories that the manufacturer provides or that obey the local rules The EVSE AC input is intended for a hardwired installation that complies with the applicable national regulations Danger General risk If you use the EVSE in any other way than described in the related documents you can cause death injury and damage to property Use the EVSE only as intended 2 3 Product label IEC portfolio XXX XXXX...

Page 12: ...Y zxxxx PN XXXXXXXXXX MODEL Terra AC WX P8 XX XXX X TAC Wx L WWYY zxxxx XXXX XXXXXX For use with electric vehicles Pour utilisation avec des véhicules électriques 240V 60Hz 32A TYPE 3 30ºC 50ºC Ventilation Not Required Aucune ventilation requise Raintight Étanche à la pluie Weight 7 0kg Dusttight Étanche à la poussière Poids 7 0kg A B C D E F G H A Serial number B Part number of the EVSE C Product...

Page 13: ... and to keep the EVSE in position AC grid input To supply the electricity to the EVSE EV charge cable To conduct the current from the EVSE to the EV EV The EV of which the batteries need to be charged Parking space Location for the EV during the charge session RFID card or smartphone To authorize the user to use the EVSE 2 5 2 Overview of the EVSE outside Note The illustration shows the EVSE model...

Page 14: ...enings Openings for the cables that go into the EVSE LED indicators To show the status of the EVSE and the charge ses sion Refer to section 2 7 1 Cabinet cover To prevent a user to access the installation and main tenance parts of the EVSE Enclosure To reduce the accessibillity of unqualified persons to the inside of the EVSE RFID reader To authorize the start or stop of a charging session with an...

Page 15: ...enance cover To prevent access to the electrical components of the EVSE Primary Ethernet connec tion To connect the Ethernet cable Socket for a Nano M2M SIM card To connect the EVSE to the internet 4G Smart meter connection To connect the cables for Modbus RTU RS485 Terminal block for dry con tacts input and output Not used Terminal block for the AC input To connect the AC input cable from the gri...

Page 16: ...t connec tion To connect the Ethernet cable Electrical pulse connector Use for manufacturer only Do not change or connect cables to this input yourself Socket for a Nano M2M SIM card To connect the EVSE to the internet 4G Terminal block for the AC input To connect the AC input cable from the grid Secondary Ethernet con nection To use one Ethernet cable connection for multiple EV SEs There is no co...

Page 17: ...nts of the EVSE Primary Ethernet connec tion To connect the Ethernet cable Socket for a Nano M2M SIM card To connect the EVSE to the internet 4G Secondary Ethernet con nection To use one Ethernet cable connection for multiple EV SEs There is no communication between the EVSEs Smart meter connection To connect the cables for Modbus RTU RS485 Terminal block for dry con tacts input and output Not use...

Page 18: ...omponents of the EVSE Primary Ethernet connec tion To connect the Ethernet cable Socket for a Nano M2M SIM card To connect the EVSE to the internet 4G Terminal block for the AC input To connect the AC input cable from the grid Secondary Ethernet con nection To use one Ethernet cable connection for multiple EV SEs There is no communication between the EVSEs Smart meter connection To connect the cab...

Page 19: ...2 6 Options 2 6 1 Display A A Display For more data about the display refer to section 2 9 2 6 2 EV charge cable Type 2 2 6 3 Socket Type 2 A A Socket Description BCM V3Y00 0 EN 002 19 ...

Page 20: ... maximum capacity The total power demand of the devices that use the grid connection must not exceed the grid capacity The load management feature prevents that the system exceeds the grid capacity and prevents damage of the fuses At times when the current demand is high the EVSE decreases the output of current The current will increase again when there is availability on the grid Also the load ma...

Page 21: ...authorization LED D Internet connection LED E EVSE on off LED Table 1 Error LED Status of the LED Status of the EVSE On Error Off No error Table 2 Charging LED Status of the LED Status of the EVSE On EV is fully charged or has stopped charging Off Not charging Flashing Charging Description BCM V3Y00 0 EN 002 21 ...

Page 22: ... Status of the LED Status of the EVSE On Connected to the internet Off Not connected to the internet Flashing In progress to establish internet con nection Table 5 EVSE on off LED Status of the LED Status of the EVSE On The EVSE is on Off The EVSE is off Flashing The EVSE is in setup 2 8 Description of the ChargerSync app for the EVSE The ChargerSync app is available on the Apple Store and on the ...

Page 23: ... the current menu Main screen area This area shows information about the status of the EVSE the charge sessions and the available menus Navigation bars To navigate through the menus of the app and to use the functions For a description of the buttons refer to section 2 8 2 2 8 2 General description of the buttons and colors Button Name color Description Home To go to the main menu Start button To ...

Page 24: ... Description Login menu Shows the fields to log in Account menu Shows the personal preferences and settings Setup menu Shows the screens to set up the EVSE Main menu Shows Navigation buttons Buttons to manage the charge session Information about the current charge session Schedule menu To create a schedule for a charge session Energy plan menu To select an energy plan for the charge session Load b...

Page 25: ...1 Boot screen During the start up of the EVSE the display shows the Boot screen 2 9 2 Standby Idle screen Total 325 634 622 KWh 30 07 2020 10 30 SN TACW2240120G4567 v 00 55 19 A B C D E A Total delivered energy B Date C Guide D Serial number E Firmware version MID certified The display shows the Standby Idle screen when the EVSE is in idle status Then the EVSE is available for a charge session 1 I...

Page 26: ... 00 55 19 The display shows this Authorization screen when the charge session is authorized but the EV charge cable is not connected to the EV 30 07 2020 10 30 Total 325 637 622 kWh SN TACW2240120G4567 v 00 55 19 2 9 4 Preparing to charge screen 30 07 2020 10 30 Total 325 637 622 kWh SN TACW2240120G4567 v 00 55 19 2 9 5 Charging screen The display shows the Charging screen during the charge sessio...

Page 27: ... 86A 60 541kWh 02 41 21 9 kW SN TACW2240120G4567 Total 325 637 622 kWh v 00 55 19 A A Real time voltage and current per phase 2 9 6 Charging completed screen 30 07 2020 09 35 30 07 2020 06 54 30 07 2020 09 35 60 541kWh 02 41 SN TACW2240120G4567 v 00 55 19 Total 325 637 622 kWh A B A Start and end time B Energy delivered and duration of the charge session 2 9 7 Fault detected display messages The d...

Page 28: ...40120G4567 v 00 55 19 A A Error code Contact your service provider 0x0010 30 07 2020 09 35 Total 325 637 622 kWh SN TACW2240120G4567 v 00 55 19 A A Error code The EV is not ready for the charge session 30 07 2020 10 30 Total 325 637 622 kWh SN TACW2240120G4567 v 00 55 19 Description 28 BCM V3Y00 0 EN 002 ...

Page 29: ...a or information The manufacturer is not liable for damages and or losses related to such security breaches any unauthorized access interference intrusion leakage and or theft of data or information 3 2 Responsibilities for the owner The owner is the person who runs the EVSE for commercial or business purposes for itself or leaves it to a third party for use During operation the owner bears legal ...

Page 30: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving...

Page 31: ...al the local rules will apply If and to the extent permitted by law in case of inconsistency or contradiction between any requirements or procedure contained in this document and any such local rules obey the stricter between the requirements and procedures specified in this document and the local rules 3 7 Safety instructions for use In these situations do not use the EVSE and immediately contact...

Page 32: ...potential hazardous substances With the correct disposal of this product you contribute to reuse and recycling of materials and protection of the environment Obey the local rules to discard parts packaging material or the EVSE Discard electrical and electronic equipment separately in compliance with the WEEE 2012 19 EU Directive on waste of electrical and electronic equipment As the symbol of the ...

Page 33: ...not use this product if the flexible power cord or EV charge cable is frayed has broken insulation or any other signs of damage Do not use this EVSE if the enclosure or the EV connector is broken cracked open or shows any other indication of damage Install an insulated grounding conductor that is identical in size insulation material and thickness to the grounded and ungrounded branch circuit supp...

Page 34: ...e EVSE 1 Close the breaker that supplies the power to the EVSE Warning Hazardous voltage Be careful when you work with electricity The power supply comes on A series of self checks start to make sure that the EVSE works correctly and safely If the EVSE detects a problem the error LED comes on The ChargerSync app shows the description of the error 4 3 Connect the EVSE with the ChargerSync app Preli...

Page 35: ...on During the charge session do not disconnect the EV charge cable There is a risk of damage of the socket of the EVSE or the connector of the EV Note The LEDs show the status of the charge session 1 Connect your EV charge cable to the connection on your EV 2 Use your RFID card or ChargerSync app to authorize for use of the EVSE The authorization of the connection to the EV starts 3 Connect the EV...

Page 36: ...is completed The ChargerSync app shows that the charge session is completed The charging LED is on If your EVSE has a display the display shows that the charge session is completed When the charge session is completed the EVSE disconnects the power supply automatically Authorize the ending of the use of the EVSE with your RFID card or the ChargerSync app The authorization of the disconnection to t...

Page 37: ... charge session is completed the EVSE disconnects the power supply automatically Authorize the ending of the use of the EVSE with your RFID card or the ChargerSync app The authorization of the disconnection to the EV starts 2 Disconnect the EV charge cable from the socket of the EVSE 3 Disconnect the EV charge cable from the connector on the EV 4 7 Wrap the EV charge cable around the enclosure 1 W...

Page 38: ... leak into the cabinet Note When the EVSE is put in a corrosion sensitive environment superficial rust is possible on welding points This rust is only visual There is no risk for the integrity of the cabinet The procedure below removes the rust Procedure 1 Rinse with low pressure tap water to remove rough dirt 2 Apply a a solution of cleaning agent to the cabinet and let it soak 3 Manually remove ...

Page 39: ... Damage Charge cables outlets and connectors Cracks or ruptures Internal wires of the cable are visible Display Cracks Coating of the cabinet Cracks or ruptures 2 If you see damage contact the manufacturer Refer to section 1 12 Maintenance and cleaning BCM V3Y00 0 EN 002 39 ...

Page 40: ...rrectly or neutral and phase wires are swapped Contact your local representative of the manufacturer or a qualified electrical contractor Refer to sec tion 1 12 Over voltage 0x0008 The maximum voltage on the power input is too high Contact your local representative of the manufacturer or a qualified electrical contractor Refer to sec tion 1 12 Under voltage 0x0010 The voltage on the power input is...

Page 41: ... or a qualified elec trical contractor Refer to sec tion 1 12 Internal communi cation failure 0x0800 The internal boards of the EVSE fail to communicate with each other 1 Connect the EVSE to the inter net 2 Do a check of the WiFi signal at the site 3 Do a check of the Nano SIM card connection and the 4G signal strength at the site E Lock failure 0x1000 Error to lock unlock the charge connector 1 E...

Page 42: ...he charge LED to make sure that the charging session is authorized 4 Start the charging session The EV charge cable is de fective 1 Examine the EV charge cable 2 If the EV charge cable is de fective contact your local rep resentative of the manufac turer or a qualified electrical contractor Refer to section 1 12 The EV connection or authorization process fails The EV charge cable is de fective 1 E...

Page 43: ...aks into the ground 1 De energize the EVSE Refer to section 6 4 2 Contact your local representa tive of the manufacturer or a qualified electrical contractor Refer to section 1 12 PE missing or swap neutral and phase 0x0004 The EVSE is not earthed correctly or neutral and phase wires are swapped Contact your local representative of the manufacturer or a qualified electrical contractor Refer to sec...

Page 44: ...r relay fault 0x0400 The relay contact is detec ted in wrong state or has damage 1 Examine the relay contact 2 If necessary contact your lo cal representative of the man ufacturer or a qualified elec trical contractor Refer to sec tion 1 12 Internal communi cation failure 0x0800 The internal boards of the EVSE fail to communicate with each other 1 Connect the EVSE to the inter net 2 Do a check of ...

Page 45: ...on 2 Examine the EVSE to find if is working correctly 3 Examine the ChargerSync app and the charge LED to make sure that the charging session is authorized 4 Start the charging session The EV charge cable is de fective 1 Examine the EV charge cable 2 If the EV charge cable is de fective contact your local rep resentative of the manufac turer or a qualified electrical contractor Refer to section 1 ...

Page 46: ...tion 1 12 There is a problem with the ChargerSync app or the RFID card 1 Make sure that you have reg istered in the ChargerSync app 2 Make sure that you use a RFID card that the manufacturer provided 3 Make sure that the RFID card is added on the ChargerSync app 4 Start the ChargerSync app 5 Start the authorization proc ess 6 4 De energize the EVSE 1 Open the breaker that supplies the power to the...

Page 47: ...4 Cable type or sock et P Type 1 cable G Type 2 cable T Type 2 socket S Type 2 socket with shutter A5 Cable length No cable 5 5 m 8 8 m A6 Authorization R RFID enabled No RFID A7 Display D Yes No A8 Metering M Certified for MID only with display Not certified for MID A9 SIM slot C Yes No A10 Ethernet Single D Daisy chain Example Terra AC W7 P8 RD MCD 0 A1 Brand name Terra AC A2 Type wallbox A3 7 P...

Page 48: ...and MID cer tificate Three phase Three phase with display and MID cer tificate UL portfolio Single phase Single phase with display IP or NEMA rating The product label shows the specification Refer to section 2 3 IK rating according to IEC 62262 en closure and display IK10 IK8 for an operation temperature be tween 35 and 30 C Codes and standards IEC 61851 21 2 EN 61000 6 1 EN 61000 6 2 EN 61000 6 3...

Page 49: ...ication Mechanical environment M1 Shock and vibrations of low significance Electromagnetic environment E2 7 4 Ambient conditions Parameter Specification Operation temperature 35 C2 to 50 C Operation temperature for MID certified models 30 C to 55C Storage temperature 40 C to 80 C Storage conditions Indoor dry Relative humidity 95 non condensing 7 5 Noise level Parameter Specification Noise level L...

Page 50: ...Y2 Y1 X Z2 X Width of the EVSE Y1 Depth of the EVSE Y2 Depth of the socket Z1 Height of the EVSE Z2 Distance from the bottom of the EVSE to the center of the socket Parameter Specification mm X 195 Y1 110 Y2 33 Z1 320 Z2 70 Technical data 50 BCM V3Y00 0 EN 002 ...

Page 51: ...EV charge cable Z Y X X Width of the EVSE Y Depth of the EVSE Z Height of the EVSE Parameter Specification mm X 195 Y 110 Z 320 7 6 3 Space requirements for installation Z2 Z1 A A EVSE Technical data BCM V3Y00 0 EN 002 51 ...

Page 52: ...th fault including DC leakage protec tion3 Integrated surge protection 7 7 2 AC input specifications IEC portfolio Parameter Specification Input AC power connection 1 phase or 3 phase Input voltage 1 phase 230 V AC Input voltage 3 phase 400 V AC Standby power consumption 4 6 W Earth ground fault protection 30mA AC 6 mA DC Maximum input power 1 phase 3 7 kW 16 A 7 4 kW 32 A Maximum input power 3 ph...

Page 53: ...output voltage range 3 phase 400 V AC Connection standard Type 2 cable Type 2 socket Type 2 socket with shutter According to IEC 62196 1 IEC 62196 2 Current for MID certified models 0 25 5 32 A 7 8 2 AC output specifications UL portfolio Parameter Specification AC output voltage range 240 V AC 1 phase Connection standard Type 1 cable according to SAE J1772 7 9 Cleaning specifications Parameter Spe...

Page 54: ......