Table 9: Outside parts of the Terra AC and function
Overview of the Terra AC, outside
J
Legend
Part
Function
A
Holster inlet
To store the charge connector
B, C and D
Openings
Openings for the cables that go into the Terra AC
E
LED indicators
To show the status of the Terra AC and the charge session. Refer to section
LED indicators on the next page
F
Cabinet cover
To prevent a user to access the installation and maintenance parts of the Terra AC
G
Enclosure
To reduce the accessibility of unqualified persons to the inside of the Terra AC
H
RFID reader
To authorize the start or stop of a charging session with an RFID card
I
Product label
To show the identification data of the Terra AC
J
Display
K
SAE J1772, type 1
charge connector
Load management
Load management makes sure that the available electrical
capacity of the building or home is not exceeded. A number
of devices share a grid connection, that has a maximum
capacity. The total power demand of the devices that use
the grid connection must not exceed the grid capacity.
The load management feature prevents that the system
exceeds the grid capacity and prevents damage of the
fuses. At times when the current demand is high, the EVSE
decreases the output of current. The current will increase
again when there is availability on the grid. Also, the load
management feature makes sure that the available load is
optimally shared.