Wire stripper pliers, cable
lug tool and torque socket
wrench. Refer to section
Procedure
1. Prepare the wire:
a. Cut the PE wire (A). Make sure
that the length is sufficient for
connection at the PE busbar (B).
b. Strip the insulation from the end
of the wire. Make sure that the
strip length is compatible with the
cable lug (C).
c. Attach the cable lug to the end of
the wire. Use the cable lug tool.
2. Attach the PE wire to the PE busbar.
Use the fasteners (D).
3. Tighten the fasteners to the correct
torque. For the specification, refer to
section
5.6.3
Connect the enclosure to the earth
Preliminary requirements
•
Installation engineer
•
•
Make sure that the earthing
connection is in accordance
with with the standard IEC
60364-5-54.
•
Cable lugs and fasteners.
.
Procedure
1. Connect the earthing conductor (B) to
the pin (A) of the enclosure.
2. Connect the earthing conductor to the
earthing electrode (C).
Note: It is possible
to connect more that
one EVSE to a single
earthing electrode, if sized
accordingly.
B
A
D
C
A
B
C
B
Installation
50
9AKK108466A3703-EN | 001