background image

Quick Start Guide

TCC300 Tapchanger Control

1

LCD SCREEN

Pressing any push button will wake up the LCD and display the heading corresponding to the “Hot Button” label 
inside the push button - WAKE, MNTR, SETP, CNFG, COMM, UTIL, or VR.

2

EXIT/WAKE 
Push button

The EXIT WAKE Push button wakes the LCD from sleep mode and begins scrolling through a list of user pro-
grammed metered/calculated values.

3

VR Pushbutton

Activates the user defined Voltage Reduction Steps

Shortcuts/arrows

4

SETP

Access to the Setpoints screens

5

MNTR

Access to the Monitoring screens

6

ENT/UTL Push button

Access to the Utilities screens and enter button

7

CNFG

Access to the Configuration screens

8

COMM

Access to the Communication screens

9

LEDS

See page 2

10

USB Port

Out of Band High Voltage

11

Smart FlashCard Slot

Used for loading and saving setpoints, DNP files and IEC 61850 CID files, saving datalog, SOE and OSC files, clone 
saving and uploading, updating firmware, saving Wakeup screen parameters and all metering parameters,  and can 
be used as an Access Code Key.

1

6

9

3

8

2

4

5

7

10

11

Summary of Contents for TCC300

Page 1: ...Voltage Reduction Steps Shortcuts arrows 4 SETP Access to the Setpoints screens 5 MNTR Access to the Monitoring screens 6 ENT UTL Push button Access to the Utilities screens and enter button 7 CNFG A...

Page 2: ...two periodic flashes indicates Level 2 Voltage Reduction Continuous illumination and three periodic flashes indicates Level 3 Voltage Reduction MANUAL LED Indicates automatic control is disabled and i...

Page 3: ...13 14 15 16 17 18 19 20 21 22 23 24 Fuse Amp Voltage Input Polarity Load Current Return See Note 2 Voltage Input Return See Note 2 Load Current Polarity 0 2 A Circulating Current Polarity 0 2A Circul...

Page 4: ...ng the current inputs Exercise care during installation operation and maintenance procedures The equipment described in this manual contains voltages high enough to cause serious injury or death Only...

Page 5: ...l xx Min Demand Load Voltage xxx x Volts Demand Pri Current xxx x Amps Demand Pri Watts x xx MW Demand Pri VArs x xx MVArs Demand Pri VA x xx MVA Demand Interval xx Min Min Load Voltage E x x Volts Ma...

Page 6: ...Power Flow Fwd 1 Bandcenter Fwd xxx x Volts LDC X Fwd x Volts Bandwidth Fwd x x Volts LDC Z Fwd x Volts LDC R Fwd x Volts With LDC R X With LDC Z Definite Inverse Delay Fwd xx Sec Bandcenter Rev xxx...

Page 7: ...er Display Option SINGLE_PHASE Fast Volt Recovery disable Fast Volt R Setting x x V Regulator Type TYPE A Output Selection CONTINUOUS Output Pulse X X Sec Low Current Block disable Tap Limits ENABLED...

Page 8: ...KT DVAR2 Sensitivity x x DVAR2 Reac I Lmt xxx mA DVAR2 I Ratio x xx Paralleling Type MASTER FOLLOWER MASTER FOLLOWER NONE Paralleling Address xx Num Devices x T P R Timeout xxxxx ms Breaker Option xxx...

Page 9: ...Validation disable Substation Address DNP x Feeder Address DNP x Comm Address DNP 1 Mdbus 1 Baud Rate 9600 Parity NONE Stop Bits ONE STOPBIT Sync Time 2 mS Output Pulse 1 5 Sec Comm Access Security d...

Page 10: ...S Coefficient 8192 X Circ Cal Coefficien 32767 X Circ Sin Coefficient 0 X Circ Cos Coefficient 8192 X LED Scroll Test Press ENT to begin Input Test Press ENT to Begin Output Test Press ENT to test But...

Page 11: ...11...

Page 12: ...ht 2016 ABB All rights reserved Contact us ABB Inc EPMV Distribution Automation 4300 Coral Ridge Drive Coral Springs FL 33065 USA Phone 1 800 523 2620 Phone 1 954 752 6700 Fax 1 954 345 5329 www abb c...