6
BAUD RATE
CONFIGURATION
SERIAL COMMS
PARITY
IDENTITY
9600
4800
2400
1200
ODD
EVEN
NONE
1
99
•1
•1
•1
Page Header –
Serial Communication Configuration Page
.
Transmission Rate
Select the transmission rate required (1200 slowest, 9600 fastest).
Parity
Select the appropriate parity to match the computer terminal or host
computer.
Identity
Assign the recorder an identification number (1 to 99). The identification
number allows more than one recorder to be accessed via the
communications channel.
Return to
Serial Communication Configuration
frame.
…3
ADVANCED CONFIGURATION LEVEL
3.1
Serial Communication Configuration Page
Information.
•
Modbus protocol.
•
Programmable baud rate (1200 to 9600 baud).
•
Odd or even parity.
The general programming procedure is as detailed in the
User Guide – Section 2.
•1 The instrument is dispatched programmed with these Company Standard Settings