Page 1: ...Ethernet Adapter Product Guide SPA ZC 402...
Page 2: ......
Page 3: ...les ethernet access to an IED using the SPA over TCP IP and Mod bus over TCP IP The SPA ZC 402 acts as a communication adapter between the SPA bus and the IEC 61850 8 1 station bus The SPA ZC 402 maps...
Page 4: ...imode glass fibre transceiver LC multimode glass fibre transceiver Optical fibres See fibre optic quides SPA ZF Optical glass fibres multimode graded index type specifications 1MRS755371 Plastic core...
Page 5: ...tests and conditions Recommended service temperature range 10 55 C continuous Limit temperature range short term 40 70 C Transport and storage temperature range 40 85 C according to the IEC 60068 2 48...
Page 6: ...y 50 Hz magnetic field According to the IEC 61000 4 8 300 A m continuous Electromagnetic emission tests Conducted RF emission Mains term Radiated RF emission According to the EN 55011 EN 55011 class A...
Page 7: ...or the IED in question References Related documents SPA ZC402MMPA Ethernet connector type M MTRJ L LC R RJ 45 Protocol type M Modbus TCP E IEC 61850 S SPA TCP Device type Optical transmitter and recei...
Page 8: ...ABB Oy Distribution Automation P O Box 699 FI 65101 Vaasa FINLAND Tel 358 10 22 11 Fax 358 10 224 1094 www abb com substationautomation...