background image

SWITC H

 

D ISCO NNEC TO R FUSE,

 

XRG 00

28

Summary of Contents for Slimline XRG00

Page 1: ... INSTA LL AT ION I NSTRUCTION Switch Disconnector Fuse Slimline XRG00 Switch Disconnector Fuse Slimline XRG00_rev C 1SEQ100098P0001 ...

Page 2: ... Table of contents 01 Use of symbols 07 10 ITS 12 EFM Motor operation 14 Fuse replacement 15 Accessory 04 Busbar overview Manual operation 06 ...

Page 3: ...omething other than electrical equipment may cause physical injury to a person or damage to equipment Use of symbols Caution Provides important information or warns about a situation that may have a detrimen tal effect on equipment Information Provides important information about the equipment SWITCH DISCONNECTOR FUSE XRG00 Tools Shows the needed tools for mounting or fastening ...

Page 4: ...t be placed into service im mediately store the switch on its original package in a clean dry location To prevent condensation maintain a uniform tempera ture Store the unit in a heated building al lowing adequate air circulation and protec tion from dirt and moisture Storing the unit outdoors could cause harmful conden sation inside the switch enclosure HAZARD OF EQUIPMENT OVERTURNING When moving...

Page 5: ...ric power Assume that all circuits are live unless they are completely deenergized tested grounded and tagged Pay particular at tention to the design of the power sys tem Consider all sources of power in cluding the possibility of backfeeding Turn off switch before removing or mak ing load side connections Always use a properly rated voltage sens ing device at all line and load to confirm switch i...

Page 6: ...4 Busbar overview SWITCH DISCONNECTOR FUSE XRG00 A B C D F E A B C D E F 50 5 2p 100 75 5 50 5 3p 50 50 75 5 50 5 4p 50 50 50 75 5 50 10 2p 100 75 10 50 10 3p 50 50 75 10 50 10 4p 50 50 50 75 10 ...

Page 7: ... Busbar overview A B C D E F 185 10 2p 370 77 5 10 185 10 3p 185 185 77 5 10 185 10 4p 185 185 97 5 77 5 10 A B C D F E 5 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 8: ... Manual operation SWITCH DISCONNECTOR FUSE XRG00 6 4 4 4 4 3 Max 4Nm Max 4Nm 45 1 2 3 M6 thread forming screw not included ...

Page 9: ... Motor operation 5 6 6 1 45 2 4 7 SWITCH DISCONNECTOR FUSE XRG00 3 3 Max 4Nm Max 4Nm 45 1 2 4 Pos 3 6 M6 thread forming screw not included Pos 5 M5X8 thread forming screw with a TX30 head included ...

Page 10: ...Close Open 2 1 Motor operation SWITCH DISCONNECTOR FUSE XRG00 8 Front cover must be locked before operating Signal 0 5 sec or permanent Manual operation long hexagon bit size 3mm approx 40 revolutions ...

Page 11: ...NNECTOR FUSE XRG00 Q1 X1 Motor multiplug connect diagram is different from ITS Motor configurations Refer to the ITS page of instruction Will go to NO at loss of 24V power supply even when the XRG apparatus is in closed position For indication purposes only ...

Page 12: ... Order code 1SDA066989R1 The Ekip Connect software tool can be downloaded for free at http library abb com 1 2 10 SWITCH DISCONNECTOR FUSE XRG00 Indicator LED s V1 Power Alive V2 Valid comm message received V3 Fuse blown V4 S1 Local remote USB connector for PC Laptop ITS with TCP Module The TCP Module Order code 1SDA104052R1 has to use Ethernet cable RJ45 Shielded Twisted Pair CAT5 or above ...

Page 13: ...ule with plastic sleeve max 0 25 mm2 1 5 mm2 1 5 mm2 0 75 mm2 Modbus communication and configuration Default setting 19200 E 8 1 Default Modbus addr 247 Baudrates 9600 19200 Parity stop start bits E 8 1 O 8 1 N 8 2 N 8 1 Modbus address range 1 247 Configuration tool Ekip connect Ekip T P cable kit needed when connecting a laptop to the ITS2 1 or ITS2 D unit for configuration Termination resistor N...

Page 14: ...DC L1 L2 L3 N K1 Electronic Fuse Monitor EFM V1 Fuse OK V2 Fuse s Blown X1 Multiplug Terminals Q1 Switch disconnector Fuse K1 Electronic Fuse Monitor EFM V1 Fuse OK V2 Fuse s Blown X X1 Multiplug Terminals 1 Q1 11 NO 13 NC 12 NO NC X1 11 NO 13 NC 12 NO NC Q1 V1 V2 Q1 in open state V1 V2 F Q1 in open state 1 F2 F3 F1 F2 1 K K1 Q1 Switch disconnector Fuse ...

Page 15: ...kV However by insulation test we recommend that the EFM module can be completely removed by also disconnecting the internal plug to the rear side of the Multiplug This will also avoid leakage current between the main phases EFM is powered by the XR busbar contacts and it starts to operate once the XR switch is in close position ...

Page 16: ... Fuse replacement 4Nm NH BS 14 SWITCH DISCONNECTOR FUSE XRG00 Hex socket 8 mm ...

Page 17: ... Accessory Guide rail 15 SWITCH DISCONNECTOR FUSE XRG00 M6X16 thread forming screw with a TX30 head included ...

Page 18: ... Accessory 4 1 2 3 Multiplug 16 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 19: ... Accessory 1 3 2 4 M6 9Nm M8 15Nm 2 5Nm 2Nm 2 4 Contact extension 17 SWITCH DISCONNECTOR FUSE XRG00 Pos 2 4 TX20 head fasteners included Pos 3 bolt and nut hex socket 13 mm fasteners included ...

Page 20: ... 7 8 1 2 4 5 7 8 3 6 9 10 11 Accessory CT 18 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 21: ... Accessory T1 S2 T1 S1 A S2 T1 S1 S1 S2 X3 1 X3 5 insulation tube A meter 1 2 3 4 8 7 6 5 Pin 1 mark X3 19 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 22: ... snap out or in the multiplug to access or break connection 4 Accessory 6 Auxiliary switch 20 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 23: ...24VDC Field common Field open Field closed PositionfeedbackNO EFM NC EFM NO NC 11 18 17 16 15 14 13 12 19 20 EFM NO Neutral 0V Aux switch EFM NC EFM NO NC Aux switch Aux switch 1 6 5 4 3 2 C T No 1 C T No 3 C T No 2 1 1 6 5 4 3 2 C T No 1 C T No 3 C T No 2 1 Accessory Auxiliary switch 21 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 24: ... Accessory 1 3 2 4 5 Switch replacement tool 22 SWITCH DISCONNECTOR FUSE XRG00 ...

Page 25: ... socket 13mm 2 Open the 3 pole cable shroud and cover it onto the cables 3 Close the 3 pole cable shroud 4 Insert the 3 pole cable shroud 5 Install the 4th pole cable 6 Insert the 4th pole cable shroud 23 SWITCH DISCONNECTOR FUSE XRG00 15 Nm 16 120 mm 12mm ...

Page 26: ...ll the MNS arc protection back cover to the electrical cabinet 2 Install 3 pole switch to the electrical cabinet SWITCH DISCONNECTOR FUSE XRG00 Note For XRG00 50 5 3P 3P version needs to mount one back cover 4P version needs to mount two back covers ...

Page 27: ...l 3 pole switch to the electrical cabinet RBBS arc protection back cover for XRG Note For XRG00 50 10 3P mounts one back cover in Xline 50mm Compact cabinets For XRG00 50 10 3P with contact extensions mounts one back cover in Xline 50mm Enlarged cabinets SWITCH DISCONNECTOR FUSE XRG00 25 ...

Page 28: ... Notes SWITCH DISCONNECTOR FUSE XRG00 26 ...

Page 29: ... SWITCH DISCONNECTOR FUSE XRG00 27 ...

Page 30: ... SWITCH DISCONNECTOR FUSE XRG00 28 ...

Page 31: ...SWITCH DISCONNECTOR FUSE XRG00 29 ...

Page 32: ...er P O Box 622 FI 65101 Vaasa Finland https new abb com contact centers Copyright 2019 ABB All rights reserved Specifications subject to change without notice Slimeline XRG00 rev C 1SEQ100098P0001 Low Voltage Products and Systems ...

Reviews: