background image

 

 

 

2TLC172249M0201, rev. B 

www.abb.com/jokabsafety 

2013-04-10 

4  Installation and maintenance 

Installation and maintenance 

1.  The installation of all ABB Jokab Safety interlock switches must be done in accordance with a risk assessment 

for the individual application. Installation must only be carried out by competent personnel and in accordance 

with these instructions.  

2.  The use of a safety relay is required for monitoring coded switches. These relays monitor 2 redundant circuits 

as per ISO13849-1 for up to PL e / Category 4 protection. Coded non-contact switches are designed to operate 

with most dual channel safety relays to satisfy IEC 60947-5-3 PDF-S. 

3.  M4 mounting bolts must be used to fix the switches. Tightening torque for mounting bolts to ensure reliable 

fixing is 1.0 Nm. 
Installation on ferrous materials may reduce the sensing distance. 
The recommended setting gap is 5 mm. The Safety switch must not be used as a mechanical stop or be 

adjusted by striking with a hammer. 
The actuator must not be allowed to strike the switch. Do not mount adjacent switches or actuators closer than 

30mm. Typical misalignment tolerance after setting is 5 mm. 

4.  After installation always check each switch function by opening and closing each guard individually in turn and 

ensuring that the Green LED on the switch and the LED’s on the safety relay are illuminated when the switch is 

closed and are extinguished when the switch is open. 

5.  Check that the machine stops and cannot be re/started when each switch is open.  

 

Warning!

 All the safety functions must be tested before starting up the system. 

Maintenance 

Monthly:

 Check alignment of actuator and look for signs of mechanical damage to the switch casing. Check wiring 

for signs of damage. 

Every 6 months:

 Check each switch function by opening and closing each guard individually in turn and ensuring 

that the Green LED on the switch and the appropriate LED’s on the safety relay are illuminated when the switch is 
closed and are extinguished when the switch is open. Check that the machine stops and cannot be re-started when 

each switch is open. 

 

Warning!

 The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that 

all the safety functions are working properly. 

 

Warning!

 

In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or 

reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, 

impairing the safety of the device which in turn could lead to serious injury to personnel. 

Caution!

 ABB Jokab Safety will not accept responsibility for failure of the switch functions if the installation and 

maintenance requirements shown in this sheet are not implemented. These requirements form part of the product 

warranty. 

 
 
 

 
 
 

Note that the red model (Sense7) is obsolete. 

It is only the stainless steel model (Sense7Z) that is active.

Summary of Contents for Sense 7 Series

Page 1: ...gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Original instructions Sense7 series Non contact coded safety switch Note that the red model Sense7 is obsolete It is only the stainless stee...

Page 2: ...ion documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in comb...

Page 3: ...ption 5 3 Connections 6 Connection 6 Cable configurations 6 Pin configurations 6 4 Installation and maintenance 7 Installation and maintenance 7 Maintenance 7 Minimum safety distance 8 5 Application e...

Page 4: ...hat the reader of this document has knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of safety devices and safety locks Knowledge of machine safety Special notes Pay a...

Page 5: ...comply with the instructions or standards especially when tampering with and or modifying the product any liability is excluded Function description The magnetic switch is small in size which makes i...

Page 6: ...actuator present Cable configurations ACTUATOR RECEIVER 1 RECEIVER 2 POWER RED 24VDC BLUE 0VDC BLACK IN WHITE OUT YELLOW IN GREEN OUT ORANGE IN BROWN OUT NC Circult 1 NC Circuit 2 NO Circult Pin confi...

Page 7: ...nated when the switch is closed and are extinguished when the switch is open 5 Check that the machine stops and cannot be re started when each switch is open Warning All the safety functions must be t...

Page 8: ...ing to the formula S K x T C Where S minimum safety distance mm K approach speed of a human body 1600 mm s T the total time from opening of the guard until the hazardous machine movement has stopped i...

Page 9: ...LC172249M0201 rev B 9 www abb com jokabsafety 2013 04 10 5 Application examples Application example Note that the red model Sense7 is obsolete It is only the stainless steel model Sense7Z that is acti...

Page 10: ...2TLC172249M0201 rev B 10 www abb com jokabsafety 2013 04 10 Note that the red model Sense7 is obsolete It is only the stainless steel model Sense7Z that is active...

Page 11: ...D Stainless Steel Sense7Z 2TLA050056R5120 5 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R6120 10 m cable 2NC 1NO LED Stainless Steel Sense7Z 2TLA050056R2120 250 mm cable with M12 2NC 1NO LED...

Page 12: ...5 mm Switching Distance target to target Sao 10 mm close on Sar 20 mm open off Tolerance to misalignment 5 mm in any direction from 5 mm setting gap Switching frequency 1 0 Hz maximum Approach speed 2...

Page 13: ...depending on system architecture EN 62061 Up to SIL3 depending on system architecture Safety data PFHD B10d Proof test interval life MTTFd 2 52 x 10 8 3 300 000 operations at 100 mA load 47 years 470...

Page 14: ...safety 2013 04 10 8 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www abb com jokabsafety Note that the red model Sense7 is obsolete It is only the st...

Reviews: