background image

Relion

®

 670 series

Busbar protection REB670

Operator's manual

Summary of Contents for RELION REB670

Page 1: ...Relion 670 series Busbar protection REB670 Operator s manual...

Page 2: ......

Page 3: ...Document ID 1MRK505209 UEN Issued February 2015 Revision E Product version 1 2 Copyright 2012 ABB All rights reserved...

Page 4: ...or disclosed only in accordance with the terms of such license Trademarks ABB and Relion are registered trademarks of the ABB Group All other brand or product names mentioned in this document may be...

Page 5: ...roduct failure would create a risk for harm to property or persons including but not limited to personal injuries or death shall be the sole responsibility of the person or entity applying the equipme...

Page 6: ...rning electrical equipment for use within specified voltage limits Low voltage directive 2006 95 EC This conformity is the result of tests conducted by ABB in accordance with the product standards EN...

Page 7: ...IED 17 Section 4 Understand the IED local human machine interface 21 Overview 21 Keypad 22 Key activated screens 23 The Help screen 23 The Reset screen 24 LCD 24 Small 24 Medium 24 LED 25 Introduction...

Page 8: ...A 35 Single phase busbar protection BZNSPDIF Zone B 35 View metering values 35 Pulse counter logic PCGGIO 35 Function for energy calculation and demand handling ETPMMTR 35 Section 7 Event list 37 Vie...

Page 9: ...Change lock 49 Differential protection 49 Three phase busbar differential protection BZNTPDIF ZoneA 49 Three phase busbar differential protection BZNTPDIF Zone B 49 One phase busbar differential prote...

Page 10: ...e busbar differential protection BZITGGIO Zone Interc 56 Single phase busbar differential protection BUSPTRC Bay 56 Single phase busbar differential protection BCZSPDIF Check zone 56 Single phase busb...

Page 11: ...ate of change frequency protection SAPFRC 60 Underfrequency protection SAPTUF 60 Multipurpose protection 61 Overview 61 General current and voltage protection CVGAPC 61 Control 61 Overview 61 Autorecl...

Page 12: ...TPDIF Check zone 71 Three phase busbar differential protection BZNTPDIF ZoneA 71 Three phase busbar differential protection BZNTPDIF Zone B 71 Three phase busbar differential protection BZITGGIO Zone...

Page 13: ...protection CVGAPC 75 Control 75 Apparatus control 75 Autorecloser SMBRREC 78 Commands 78 IEC61850 generic communication I O functions DPGGIO 79 Monitoring 79 Logical signal status report BINSTATREP 80...

Page 14: ...92 Reset busbar protection trip 92 Reset trip in Zone A Three phase 92 Reset trip in Zone B Three phase 92 Reset trip in Zone A Single phase 92 Reset trip in Zone B Single phase 92 Reset counters 92 R...

Page 15: ...Authorization handling in the IED 97 Internet Protocol ports security guideline 98 Section 15 Glossary 101 Table of contents 9 Operator s manual...

Page 16: ...10...

Page 17: ...eringmanual Commissioning manual manual Technical reference IEC09000744 V1 EN The Application Manual AM contains application descriptions setting guidelines and setting parameters sorted per function...

Page 18: ...recommends a sequence for engineering of protection and control functions LHMI functions as well as communication engineering for IEC 61850 and DNP3 1 1 2 About the operator s manual Use the operator...

Page 19: ...manual 1MRK 505 209 UEN Installation and commissioning manual 1MRK 505 210 UEN Technical reference manual 1MRK 505 208 UEN Application manual 1MRK 505 211 UEN Product guide pre configured 1MRK 505 212...

Page 20: ...14...

Page 21: ...site configuration Operating the IED without proper earthing may damage both IED and measuring circuitry and may cause injuries in the event of an accident Never remove any screw from a powered IED or...

Page 22: ...16...

Page 23: ...future reference For example the fault currents and voltages at the time of the fault can be documented The operator can also retrieve data about protected objects providing further information for f...

Page 24: ...ries product type REB REC RED REG REL RET and so on ProductDef specifies the version of the product in the following order major version minor version major revision minor revision 1 2 2 0 for example...

Page 25: ...IEDMainFunType Specifies the main IED functionality in accordance to IEC60870 5 103 numbering REL 128 compatible range REC 242 private range RED 192 compatible range RET 176 compatible range REB 207 p...

Page 26: ...20...

Page 27: ...tion on the LCD and what the LEDs indicate is explained in the sections that follow 4 1 Overview The human machine interface is used to monitor and to some extent control the way the IED operates The...

Page 28: ...d has the same look and feel in all IEDs LCD screens and other details may differ but the way the keys function is identical IEC05000153 V1 EN Figure 5 The HMI keypad Table 1 describes the HMI keys th...

Page 29: ...iting mode and confirm setting changes when in editing mode IEC05000109 V1 EN Press to navigate forward between screens and move right in editing mode IEC05000110 V1 EN Press to navigate backwards bet...

Page 30: ...cussed in the Reset chapter of this document 4 4 LCD 4 4 1 Small The small sized HMI is available for 1 2 3 4 and 1 1 x 19 case The LCD on the small HMI measures 32 x 90 mm and displays 7 lines with u...

Page 31: ...cation module comprising 15 LEDs is standard in 670 series Its main purpose is to present an immediate visual information for protection indications or alarm signals Alarm indication LEDs and hardware...

Page 32: ...e objects being monitored the operator must navigate the menu tree using the arrow keys The active submenu or value is highlighted Navigation is as follows Press the right arrow key to move to the mai...

Page 33: ...vel in the HMI tree 4 7 3 Control The HMI offers the operator the opportunity to exercise direct local control over breakers and other apparatuses in the bay using the graphic display and designated k...

Page 34: ...28...

Page 35: ...menu Control Measurements Events Disturbance records Settings Diagnostics Test Reset Authorization Language Each main menu item can have several other submenus 5 1 1 Menu tree for REB670 Main menu Sub...

Page 36: ...tial protection Current protection Control Monitoring Logic Activate setting group Diagnostics Internal events IED status Test IED test mode Binary input values Binary output values Function test mode...

Page 37: ...e current transformers CTs 2 Analog secondary values are the quantities measured on the secondary side of the current and voltage transformers These are the quantities measured on the Transformer modu...

Page 38: ...Analog primary values Displays the quantities measured by the transformer module TRM or received via IEC 61850 9 2 LE process bus For each channel used the amplitude of the current is shown If the amp...

Page 39: ...ues shown are without units 6 4 1 2 Signal matrix for mA inputs SMMI Main menu Measurements Analog mean values SMT mA modules Instance x Displays the input signals coming into the Milli ampere Module...

Page 40: ...urrent should be zero the positive sequence current should be equal to the current of each phase with the same phase angle relative to GPS as the L1 phase signal and the negative sequence current shou...

Page 41: ...rrent and differential current value 6 6 View metering values 6 6 1 Pulse counter logic PCGGIO Main menu Measurements Metering PulseCounter PCGGIO PCGGIO x The output data generated from the pulse cou...

Page 42: ...36...

Page 43: ...ew events 7 1 1 Overview Events displays recorded events such as trips and breaker opened or closed Main menu Events Displays a list of events in chronological order and where each event has a time st...

Page 44: ...38...

Page 45: ...escribed in the sections that follow 8 2 View disturbance record details 8 2 1 View general information By choosing General information after selecting a disturbance record in the list of disturbance...

Page 46: ...splayed The path in the HMI is shown below Main menu Disturbance records Record xx Trip Values 8 3 Trigger a disturbance report manually Using the manual trigger generates an instant disturbance repor...

Page 47: ...ust not be turned off Do not perform a setting change at the same time as a hardware reconfiguration Doing so might cause the IED to malfunction 9 1 System time and synchronization 9 1 1 System time M...

Page 48: ...and the detection mode 9 1 2 4 DSTBEGIN Main menu Settings Time Synchronization DSTBEGIN x The starting point for Daylight Savings Time is set here 9 1 2 5 DSTEND Main menu Setttings Time Synchronizat...

Page 49: ...9 2 1 2 Identifiers Main menu Settings General settings Power system Identifiers Displays list with Station Name Station Number Object Name Object Number Unit Name and Unit Number 9 2 1 3 Primary valu...

Page 50: ...tings Communication SLM configuration Rear optical LON port ServicePinMessage In this submenu a Service pin message can be generated This is similar to a ping in traditional networks This sends a sign...

Page 51: ...SLM configuration Rear optical SPA IEC DNP port IEC60870 5 103 When IEC 60870 5 103 is used the settings Slave address Baud rate RevPolarity and CycMeasRepTime are done here 9 2 2 4 Station communicat...

Page 52: ...and Off parameter 9 2 2 5 Ethernet configuration IEC 61850 9 2LE process bus communication is not supported in REB670 Main menu Settings General settings Communication Ethernet configuration Front por...

Page 53: ...for all of these and for the BIMs oscillation release and oscillation block settings are available These settings are on board level and apply to all binary inputs or outputs on a board 9 2 3 2 Analo...

Page 54: ...ter which enables the operator to switch the module on or off The milliampere modules MIMs are also found in the I O Modules folder Parameters possible to set here are dead band settings and various c...

Page 55: ...BZNTPDIF Zone B Main menu Settings General settings Differential protection BBPZoneB3Ph PDIF 87B BZNTPDIF_B x Parameters for this function are found here These include limits deadband values reporting...

Page 56: ...sion time to cancel a reservation and the other eight are for the reservation of the own bay only at the selection of an apparatus Circuit breaker SXCBR Main menu Settings General settings Control App...

Page 57: ...DNP3 0 AutomationBits Main menu Settings General settings Control Commands Automation bits AUTOBITS x A parameter to enable or disable the function is available Single command SINGLECMD Main menu Set...

Page 58: ...MMXU x Displays available instances of the voltage phasor function VMMXU with output data for phase to phase voltage amplitude phase angle The setting parameters for supervision levels deadband etc ar...

Page 59: ...ignals RBDR Channel xx yy There are some groups of several channels with several binary outputs per channel Each channel has some settable parameters These are operation trig level indication MA and s...

Page 60: ...are four sets of measurement settings one with standard settings and three with user defined settings The standard settings include some standard service value thresholds In the Disturbance report men...

Page 61: ...available for differential protection in Setting group N are not the same as those under General settings The main difference is that settings in the Setting group N category can be changed on the fl...

Page 62: ...neB3Ph PDIF 87B BZNTPDIF_B x There are several settings in this view which cover several aspects of this function Operation alarm settings and sensitivity levels are among the settings available here...

Page 63: ...BPZoneInterc1Ph GGIO 87B BZISGGIO x This function has two settings in this view Operation for turning the function on or off and the threshold time for the alarm 9 3 2 13 Status of primary switching o...

Page 64: ...er protection GOPPDOP Main menu Settings Setting Group N Current protection DirOverPowerProtection PDOP 32 GOPPDOP x Includes power angle and calibration factor settings 9 3 3 6 Directional under powe...

Page 65: ...e three instances of parameters in each category except in the case of Overexcitation which has two instances Each instance consists of a number of parameters that make it possible to switch the funct...

Page 66: ...ping 9 3 5 2 Overfrequency protection SAPTOF Main menu Settings Setting Group Frequency protection OverFrequency PTOF 81 SAPTOF x Displays available instances of SAPTOF with a number of settings per i...

Page 67: ...urrentVoltage GAPC CVGAPC x Displays available instances of CVGAPC with several settable parameters per instance These settings are available for the user defined functions configured with the help of...

Page 68: ...set 9 3 9 2 LogicGate Main menu Settings Setting group N Logic LogicGate GATE x Displays parameter settings for Operation On or Off 9 3 9 3 LogicRSMemory Main menu Settings Setting group N Logic Logic...

Page 69: ...r activate setting group one of these setting groups can be chosen for the application at hand 9 5 Language Under the language part of the main menu the language options available in the HMI are locat...

Page 70: ...64...

Page 71: ...item on the list To identify the type of IED you are confronted with navigate to identifiers using the keypad The path to identity parameters is shown below Main menu Diagnostics IED status Product i...

Page 72: ...arious communication status signals for rear AB port communication Main menu Diagnostics Communication Rear OEM port CD Displays various communication status signals for rear CD port communication Mai...

Page 73: ...rential Protection displays a choice of differential functions available to the operator Function related measurements can be viewed by navigating to the screen for each individual function 4 Current...

Page 74: ...the measurements menu the operator will only see data from the hardware and software installed 11 2 IED test mode Main menu Test IED test mode Displays a setting which is used to activate and deactiva...

Page 75: ...ng The names of binary outputs are changed in the setting menu 11 4 1 2 Signal matrix for binary outputs SMBO Main menu Test Binary output values SMT binary outputs Displays available sets of binary o...

Page 76: ...ontrol Main menu Test Function test modes Control Test of synchrocheck and energizing check function as well as auto reclosing function 11 5 8 Monitoring Main menu Test Function test modes Monitoring...

Page 77: ...tection BBPCheckZone3Ph PDIF 87B BCZTPDIF x Trip data for the check zone and the separate phases is presented here 11 6 2 4 Three phase busbar differential protection BZNTPDIF ZoneA Main menu Test fun...

Page 78: ...protection BZNSPDIF Zone B Main menu Test Function status Differential protection BBPZoneB1Ph PDIF 87B BZNSPDIF_B x This view shows data output with trip CT and current information 11 6 2 11 Single ph...

Page 79: ...power protection GOPPDOP Main menu Test Function status Current protection DirOverPowerProt PDOP 32 GOPPDOP x Displays the output data of GOPPDOP 11 6 3 5 Directional under power protection GUPPDUP Ma...

Page 80: ...atus Voltage protection LossofVoltage PTUV 27 LOVPTUV x Displays the output data of LOVPTUV 11 6 4 2 Two step overvoltage protection OV2PTOV Main menu Test Function status Voltage protection OverVolta...

Page 81: ...urpose protection GeneralCurrentVoltage GAPC CVGAPC x Displays available instances of CVGAPC with a number of output quantities per instance These include error signals from overcurrent functions trip...

Page 82: ...A1A2_BS x Displays the interlocking conditions that apply to the various switches and breakers Interlock bus section disconnect A1A2_DC Main menu Test Function status Control Apparatus control Interl...

Page 83: ...reaker bus B DB_BUS_B Main menu Test Function status Control Apparatus control InterlDoubleCBBusB DB_BUS_B x The outputs from this function show when closing of disconnectors and breakers is allowed a...

Page 84: ...ys available instances of the function QCBAY with three measurements per instance The operator place allocation PSTO measurement has an integer as output data whereas the Update of position is blocked...

Page 85: ...osition of each switch is indicated here There are up to a number of possible switch positions The number of switches and switch positions is determined by the configuration in the PCM configuration t...

Page 86: ...aximum number of incoming analog channels is 40 and their Trig status is indicated here The Fault number parameter generates an integer indicating the number of faults recorded since the last clearing...

Page 87: ...uts 11 6 8 9 IEC61850 generic communication I O functions SPGGIO Main menu Test Function status Monitoring SinglePointIndication GGIO SPGGIO x Displays the output data of the SPGGIO function 11 6 9 Lo...

Page 88: ...9 5 Logic timer set Main menu Test Function status Logic LogicTimerSet TIMERSET x Displays available instances of the function TIMERSET The output data type is boolean and indicates whether the output...

Page 89: ...eivingInterlInfo GOOSEINTLKRCV x The Receiving Interlock information available here indicates the state of various apparatus such as whether they are in a closed or open position and if their status i...

Page 90: ...ne differential test Main menu Test Line differential test LineDiffLogic Settings used during test of line differential protection including test mode setting With the line differential protection in...

Page 91: ...Switch function is configured in the PCM600 tool and the switch position can be changed in the HMI The selector switch has the same function as a rotating switch with up to 32 positions Each position...

Page 92: ...vsd IEC05000232 V1 EN Circuit breaker xx05000233 vsd IEC05000233 V1 EN Damping Coil xx05000234 vsd IEC05000234 V1 EN Current Transformer xx05000235 vsd IEC05000235 V1 EN Earth xx05000236 vsd IEC05000...

Page 93: ...confirm an action such as the opening of a circuit breaker They can also warn the user as to conditions that are a hindrance to the intended action such as an interlocking condition The user may be g...

Page 94: ...ser defined bay name This can only be set in the PCM software tool 2 Internally used bay FB 3 Connections to internal zones IEC06000192 V1 EN Section 12 1MRK505209 UEN E Control and supervise the bay...

Page 95: ...1 User settable switchgear names 2 Switchgear object status 1MRK505209 UEN E Section 12 Control and supervise the bay 89 Operator s manual...

Page 96: ...90...

Page 97: ...CT in Zone B Three phase Main menu Reset Reset BBP open CT BBPZoneB3Ph PDIF 87B BZNTPDIF_B x Resetting the three phase open CT in zone B is done here 13 1 3 Reset open CT in Zone A Single phase Main...

Page 98: ...in zone A is done here 13 2 1 4 Reset trip in Zone B Single phase Main menu Reset Reset BBP trip BBPZoneB1Ph PDIF 87B BZNSPDIF_B x Resetting the single phase trip in zone B is done here 13 2 2 Reset c...

Page 99: ...S to reset 13 2 2 6 LDCM clear counters Main menu Reset Reset counters LDCMCommunication LDCMX Activating Reset of LDCM counters sets the counter concerned to zero A reset can be performed by affirmat...

Page 100: ...EDs will zero all fifteen LEDs to the right of the LCD Main mnenu Reset Reset LEDs All indication LEDs In the dialog box that appears choose YES to reset 13 2 5 Reset process eventlist Main menu Reset...

Page 101: ...both access points to the IED local through the local HMI remote through the communication ports 14 2 Principle of operation There are different levels or types of users that can access or operate dif...

Page 102: ...nfiguration possibilities application configuration including SMT GDE and CMT R R W R R R R W R W File loading database loading from XML file R W R W R W File dumping database dumping to XML file R W...

Page 103: ...e or more users created with the IED User Management and downloaded into the IED then when a user intentionally attempts a Log on or when the user attempts to perform an operation that is password pro...

Page 104: ...NP communication only 20 000 UDP closed DNP3 DNP3 DNP communication only The 670 series supports two Ethernet communication protocols These protocols are IEC61850 and DNP3 TCP These communication prot...

Page 105: ...SPA and is fixed and can not be changed These security drawbacks are acceptable in limited local networks For wide area networks in particular with connection to the Internet the 670 series Ethernet...

Page 106: ...100...

Page 107: ...ZD ArgDir Setting parameter ZD ASCT Auxiliary summation current transformer ASD Adaptive signal detection AWG American Wire Gauge standard BBP Busbar protection BFP Breaker failure protection BI Bina...

Page 108: ...60255 24 Contra directional Way of transmitting G 703 over a balanced line Involves four twisted pairs two of which are used for transmitting data in both directions and two for transmitting clock sig...

Page 109: ...512 515 Access multiplexer FOX 6Plus Compact time division multiplexer for the transmission of up to seven duplex channels of digital data over optical fibers G 703 Electrical and functional descript...

Page 110: ...from the PCI SIG Special Interest Group for the electrical EMF Electromotive force IEEE 1686 Standard for Substation Intelligent Electronic Devices IEDs Cyber Security Capabilities IED Intelligent el...

Page 111: ...e carrier module MIM Milli ampere module MPM Main processing module MVB Multifunction vehicle bus Standardized serial bus originally developed for use in trains NCC National Control Centre NUM Numeric...

Page 112: ...ts RISC Reduced instruction set computer RMS value Root mean square value RS422 A balanced serial interface for the transmission of digital data in point to point connections RS485 Serial link accordi...

Page 113: ...ork layer and transport layer protocols While TCP and IP specify two protocols at specific protocol layers TCP IP is often used to refer to the entire US Department of Defense protocol suite based upo...

Page 114: ...lendar It is used for aeroplane and ship navigation where it is also sometimes known by the military name Zulu time Zulu in the phonetic alphabet stands for Z which stands for longitude zero UV Underv...

Page 115: ...109...

Page 116: ...act us ABB AB Substation Automation Products SE 721 59 V ster s Sweden Phone 46 0 21 32 50 00 Fax 46 0 21 14 69 18 www abb com substationautomation 1MRK505209 UEN E Copyright 2012 ABB All rights reser...

Reviews: