background image

IM

R

S

75

76

27 R

E

V C E

N 0

2-

20

19

We reserve the right to make technical changes or modify the contents 
of this document without prior notice. With regard to purchase orders, 
the agreed particulars shall prevail. ABB does not accept any responsibility 
whatsoever for potential errors or possible lack of information in this 
document.

We reserve all rights in this document and in the subject matter and 
illustrations contained therein. Any reproduction, disclosure to third 
parties or utilization of its contents – in whole or in parts – is forbidden 
without prior written consent of ABB. 
Copyright© 2019 ABB. All rights reserved.

Most common function blocks

Function

IEC 61850

IEC 60617

Three-phase non-directional overcurrent protection, low stage

PHLPTOC

3I>

Three-phase non-directional overcurrent protection, high stage

PHHPTOC

3I>>

Three-phase non-directional overcurrent protection, instantaneous stage

PHIPTOC

3I>>>

Non-directional earth-fault protection, low stage

EFLPTOC

Io>

Non-directional earth-fault protection, high stage

EFHPTOC

Io>>

Non-directional earth-fault protection, instantaneous stage

EFIPTOC

Io>>>

Directional earth-fault protection, low stage

DEFLPDEF

Io> →

Directional earth-fault protection, high stage

DEFHPDEF

Io>> →

Transient / intermittent earth-fault protection

INTRPTEF

Io> → IEF

Negative-sequence overcurrent protection

NSPTOC

I2>

Phase discontinuity protection

PDNSPTOC

I2/I1>

Residual overvoltage protection

ROVPTOV

Uo>

Three-phase thermal protection for feeders

T1PTTR

3Ith>F

Loss of load supervision

LOFLPTUC

3I<

Motor load jam protection

JAMPTOC

Ist>

Motor start-up supervision

STTPMSU

Is2t n<

Phase reversal protection

PREVPTOC

I2>>

Thermal overload protection for motors

MPTTR

3Ith>M

Circuit breaker failure protection

CCBRBRF

3I>/Io>BF

Three-phase inrush detector

INRPHAR

3I2f>

High-impedance differential protection

HIPDIF

dHi>

Phase segregated CT supervision function

HZCCRDIF

MCS 1I

Circuit-breaker control

CBXCBR

I ↔ O CB

Emergergency startup

ESMGAPC

ESTART

Trip circuit supervision

TCSSCBR

TCS

Runtime counter for machines and devices

MDSOPT

OPTS

Disturbance recorder

RDRE

DR

Optional
Auto-reclosing

DARREC

O → I

The most common function blocks are listed below, see the full list from the operators manual. 
Available function blocks varies depending on the selected IED and standard configuration.

Complete customer documentation is available in the product pages that 
can be accessed through 

abb.com/relion.

For more information, please contact

ABB Distribution Solutions

P.O. Box 699
FI-65101 Vaasa, Finland
Phone: + 358 10 22 11

abb.com/substationautomation

Reviews: