Operation Manual / Power2 550-M / High-pressure stage
3 Removal and installation / 3.3 Installing the high-pressure stage
© Copyright 2022 ABB. All rights reserved.
HZTL4058_EN
Rev.F
March 2022
WARNING
Support (61300)
In radial gas outlet casings, the gas forces cause high torques to act on the
high-pressure stage. If the high-pressure stage is fastened improperly, this
can damage the high-pressure stage and cause serious injuries to persons
or even fatal accidents.
u
When using a radial gas outlet casing, only operate the high-pressure
stage with a completely fitted support (61300).
Fig. 20: Steps for fastening the high-pressure stage
Part number
Thread size and tightening torque
01
M16
260 Nm
61003
M20
365 Nm
Table 10: Tightening torque (01, 61003)
3. Fit the support (61300) using the fixing screws (01). Observe tightening torque.
4. Tighten the screw (61003) of the connection between gas outlet casing (61001) and sup-
port (61300).
u
Connect all gas pipes and air lines.
Page
38
/
119