Manual Power Quality Filter PQFS
Troubleshooting guide 189
Figure 88: PQF error treatment procedure in flowchart format
In general the occurrence of transient faults is no problem for the proper operation
of the active filter. Only when an error becomes ‘critical’, a problem may exist.
If ‘ACK. FAULT’ is present on the PQF-Manager display, look at the ‘Armed’ indicator
(By default mapped to the 4
th
digital output of the PQF-Manager) to know whether
the filter will restart automatically after clearance of the problem or not.
‘Armed’ indicator ON: The filter waits for the problem to disappear and then restarts
automatically (unless the user acknowledges the fault).
‘Armed’ indicator OFF: The filter is permanently stopped and the customer has to
solve the problem, acknowledge the fault and restart the filter manually.
11.3
Spare part list for normal and dedicated filter servicing
A standard set of spare parts for the PQFS filter is shown in
Table 57: Standard set of spare parts for normal and dedicated filter servicing
Ref. Description
Order code
Recommended
quantity
1
Spare fuses for auxiliary circuit
2GCA100465A0420
3
2
Spare fuses for pre load circuit
2GCA113178A0420
2
3
PQF-Manager filter controller
(touchscreen)
2GCA291723A0075
1
4
Assy cooling “fan in” PQFS (30-100A)
2GCA294292A0075
1
5
Assy cooling “fan in” PQFS (120 A)
2GCA294290A0075
1
6
Assy cooling “fan out” PQFS (30-60A)
2GCA294800A0075
1
7
Assy cooling “fan out” PQFS (70-120A)
2GCA293805A0075
1
8
Control board Master
1
2GCA292552A0079
1
Control board Slave
1
2GCA292553A0079
9
DC Power Supply
2
2GCA116277A0530
1
10
DC power Metallic support
3
2GCA291036A0075
1
11
PCB EMC - OUTPUT FILTER PQFS
4
2GCA112522A0580
1
12
PCB EMC LINE PQFS
4
2GCA113067A0580
1
13
PCB EMC NEUTRAL PQFS
4
2GCA113068A0580
1
14
PCB EMC NEUTRAL LINE OUT FILT PREL
PQFS
5
2GCA113070A0580
1
1
Serial number including DSP and uC software versions of existing PQFS must be
communicated for suitable programming
2
For PQFS manufactured after Jan 1
st
2021
3
For PQFS manufactured before 2021