background image

 

POWERVALUE 11 RT G2 

 

STATUS 

Approved 

SECURITY LEVEL 

Public 

DOCUMENT ID. 

4NWD005580 

REV. 

LANG. 

EN 

PAGE 

6/12 

© Copyright 

[Year of first publication]

 ABB. All rights reserved. 

 

 

3.

 

Recycling advice 

The following table is intended to guide selective treatment and recycling, showing where which sub-
stances of concern are used and where they are located [ref. Directive 2012/19/EU Article 15 and Annex 
VII]. 

Substances of very high concern under Regulation (EC) No 1907/2006

(1)

 are typically used but not re-

ported in this document due to changing nature: contact ABB to get the latest declaration available. 

(1) Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH). 

 

Substance(s)/Component(s) 

Where used (potential) 

Batteries 

- As spare VRLA blocks; 

Printed circuit boards 

Used as spare and contained in fans. 

Plastic containing brominated flame retardants 
(BFRs) 

(2)

 

- PVC insulation for cables; 
- Plastic housing for signal cables’ terminals; 
- Cable ties (nylon), fasteners and supports (polyam-
ide);  
- Plastic shell for SNMP card; 
- plastic cover for touch panel; 
- plastic of plugs and receptacles. 

Liquid crystal displays (surface > 100 cm

2

Not used 

Electrolyte capacitors (

height > 25 mm, diameter > 

25 mm)

 

On selected printed circuit board 

External cables 

Provided with original package 

Mercury containing components 

Not used 

Toner cartridges 

Not used 

Asbestos containing components 

Not used 

CFC’s, HCFC’s, HFC’s, HC’s  

Not used 

Gas discharge lamps 

Not used 

Components containing refractory ceramic fibres 

Not used 

Components containing radioactive substances 

Not used 

 (2) due to assembly complexity and where-used indication, the location of these substances or material will not be indicated along the docu-
ment, unless considered necessary. 

 

Other materials and components, when not indicated above: 

High level component 

Substance(s) 

Original packaging 

Paper; 
Polyethylene foam or film 

Metallic covers (plain or painted) 

Steel, zinc plated 

Transparent air guide 

Polycarbonate 

Summary of Contents for PowerValue 11 RT G2

Page 1: ...020 09 23 DOCUMENT KIND End of life treatment OWNING ORGANIZATION ABB Electrification Smart Power business line DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 1 12 Copyright Year of first publication ABB A...

Page 2: ...l rights reserved Contents 1 Important safety instructions 3 1 1 Symbols and warnings 3 1 2 Safety rules 4 2 Introduction 5 2 1 Related to the document 5 2 2 Applicability 5 2 3 Target audience 5 2 4...

Page 3: ...SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD DANGER INDICATES AN IMMINENT ELECTRICAL HAZARD FAILURE TO OBSERVE THE RELATED SAFETY NOTE MAY CAUSE INJURY DEATH OR EQUIPMENT DAMAGE THIS SYMBOL IN CONJUNCTI...

Page 4: ...ESTABLISH IF THE BATTERY IS INADVERTENTLY GROUNDED IF INADVERTENTLY GROUNDED REMOVE SOURCE FROM GROUND CONTACT WITH ANY PART OF A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK THE LIKELIHOOD OF SUC...

Page 5: ...lue 11RT G2 1 kVA S 4NWP100200R0007 UPS PowerValue 11RT G2 2 kVA B 4NWP100201R0001 UPS PowerValue 11RT G2 2 kVA S 4NWP100201R0007 UPS PowerValue 11RT G2 3 kVA B 4NWP100202R0001 UPS PowerValue 11RT G2...

Page 6: ...nated flame retardants BFRs 2 PVC insulation for cables Plastic housing for signal cables terminals Cable ties nylon fasteners and supports polyam ide Plastic shell for SNMP card plastic cover for tou...

Page 7: ...l circuit breakers fans may contain printed circuit boards 4 Dismantling and recycling instructions DANGER RISK OF ELECTRIC SHOCK CAPACITORS AND OTHER UPS COMPONENTS MAY STORE NON LETHAL ENERGY FOR LO...

Page 8: ...s equipped with 2x extension cords 1 83 m long for AC input and output Schuko plug IEC C13 IEC C13 IEC C14 On the 3KB 3KS models they equipped with additional extension cord for the output IEC C20 IEC...

Page 9: ...first publication ABB All rights reserved 4 2 External and internal covers Remove the front plastic cover and disconnect the internal battery connector Remove all screws on the top and slide the cover...

Page 10: ...e battery tray In case of battery pack one tray is used Figure 4 5 WARNING VRLA BATTERY BLOCKS CONTAINS HAZARDOUS SUBSTANCES AS INORGANIC LEAD LEAD COMPOUNDS Pb CAS 7439 92 1 SULFURIC ACID CAS 7664 93...

Page 11: ...UE 11 RT G2 STATUS Approved SECURITY LEVEL Public DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 11 12 Copyright Year of first publication ABB All rights reserved Figure 4 6 PowerValue 11 RT G2 relevant ma...

Page 12: ...roved SECURITY LEVEL Public DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 12 12 Copyright Year of first publication ABB All rights reserved 4 2 1 SNMP card The SNMP Web Pro card is made by one PCBA see Fi...

Reviews: