1.

 

Important safety instructions 

 

THIS CHAPTER CONTAINS IMPORTANT SAFETY INSTRUCTIONS. READ IT CAREFULLY 
BEFORE STARTING DISASSEMBLING THE UNIT.   

 

 

1.1.

 

Symbols and warnings 

The following symbols are used in this manual, the list below explains each symbol. 

 

THIS SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD “

DANGER

” INDICATES AN 

IMMINENT ELECTRICAL HAZARD. 
FAILURE TO OBSERVE THE RELATED SAFETY NOTE MAY CAUSE INJURY, DEATH OR 
EQUIPMENT DAMAGE. 

 

THIS SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD “

WARNING

” INDICATES A 

POTENTIALLY DANGEROUS SITUATION. 
FAILURE TO OBSERVE MAY CAUSE INJURY, DEATH OR EQUIPMENT DAMAGE. 

 

THIS SYMBOL INDICATES A HEAVY WEIGHT OBJECT THAT CAN CAUSE INJURY IN CASE OF 
FALLING. 

 

THIS SYMBOL INDICATES SHARP EDGES THAT MAY CAUSE INJURING FROM CUTTING. 

 

DO NOT DISPOSE OF WITH ORDINARY TRASH. 

 

THIS SYMBOL INDICATES USE OF GENERIC BUTTON-LIKE BATTERY, REQUIRING 
SELECTIVE DISPOSAL. 

 

 

Summary of Contents for PowerValue 11 RT G2

Page 1: ...020 09 23 DOCUMENT KIND End of life treatment OWNING ORGANIZATION ABB Electrification Smart Power business line DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 1 12 Copyright Year of first publication ABB A...

Page 2: ...l rights reserved Contents 1 Important safety instructions 3 1 1 Symbols and warnings 3 1 2 Safety rules 4 2 Introduction 5 2 1 Related to the document 5 2 2 Applicability 5 2 3 Target audience 5 2 4...

Page 3: ...SYMBOL IN CONJUNCTION WITH THE SIGNAL WORD DANGER INDICATES AN IMMINENT ELECTRICAL HAZARD FAILURE TO OBSERVE THE RELATED SAFETY NOTE MAY CAUSE INJURY DEATH OR EQUIPMENT DAMAGE THIS SYMBOL IN CONJUNCTI...

Page 4: ...ESTABLISH IF THE BATTERY IS INADVERTENTLY GROUNDED IF INADVERTENTLY GROUNDED REMOVE SOURCE FROM GROUND CONTACT WITH ANY PART OF A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK THE LIKELIHOOD OF SUC...

Page 5: ...lue 11RT G2 1 kVA S 4NWP100200R0007 UPS PowerValue 11RT G2 2 kVA B 4NWP100201R0001 UPS PowerValue 11RT G2 2 kVA S 4NWP100201R0007 UPS PowerValue 11RT G2 3 kVA B 4NWP100202R0001 UPS PowerValue 11RT G2...

Page 6: ...nated flame retardants BFRs 2 PVC insulation for cables Plastic housing for signal cables terminals Cable ties nylon fasteners and supports polyam ide Plastic shell for SNMP card plastic cover for tou...

Page 7: ...l circuit breakers fans may contain printed circuit boards 4 Dismantling and recycling instructions DANGER RISK OF ELECTRIC SHOCK CAPACITORS AND OTHER UPS COMPONENTS MAY STORE NON LETHAL ENERGY FOR LO...

Page 8: ...s equipped with 2x extension cords 1 83 m long for AC input and output Schuko plug IEC C13 IEC C13 IEC C14 On the 3KB 3KS models they equipped with additional extension cord for the output IEC C20 IEC...

Page 9: ...first publication ABB All rights reserved 4 2 External and internal covers Remove the front plastic cover and disconnect the internal battery connector Remove all screws on the top and slide the cover...

Page 10: ...e battery tray In case of battery pack one tray is used Figure 4 5 WARNING VRLA BATTERY BLOCKS CONTAINS HAZARDOUS SUBSTANCES AS INORGANIC LEAD LEAD COMPOUNDS Pb CAS 7439 92 1 SULFURIC ACID CAS 7664 93...

Page 11: ...UE 11 RT G2 STATUS Approved SECURITY LEVEL Public DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 11 12 Copyright Year of first publication ABB All rights reserved Figure 4 6 PowerValue 11 RT G2 relevant ma...

Page 12: ...roved SECURITY LEVEL Public DOCUMENT ID 4NWD005580 REV 1 LANG EN PAGE 12 12 Copyright Year of first publication ABB All rights reserved 4 2 1 SNMP card The SNMP Web Pro card is made by one PCBA see Fi...

Reviews: