9.15
Axial clearance A after assembly
CAUTION
Clearances outside the tolerance
Serious damage to engines or property can be caused by clearances outside
the tolerance and excessively worn parts.
u
Have the components assessed and, if necessary, replaced by a Turbo
Systems service station.
Fig. 46: Measuring axial clearance A
The axial clearance (A) must be measured prior to removal and after installation of the cart-
ridge group.
u
Measure and note axial clearance (A).
Axial clearance A [mm]
0.32 ... 0.53
Table 46: Axial clearance A