![ABB PLUTO Safety-PLC Operating Instructions Manual Download Page 7](http://html.mh-extra.com/html/abb/pluto-safety-plc/pluto-safety-plc_operating-instructions-manual_3134007.webp)
7
2TLC172001M0211_A
Inputs and outputs for Pluto D20
Terminal on Pluto
In-/Output name in software
I/O type
Local/Global
IA0…IA3
I_.0…I_.3
Safe Input/
Safe Analogue input 4-20mA/0-10V
Global
I4…I7
I_.4…I_.7
Safe Input
Global
Q0
Q_.0
Safe Output (Relay)
Global
Q1
Q_.1
Safe Output (Relay)
Global
Q2
Q_.2
Safe Output (Transistor)
Global
Q3
Q_.3
Safe Output (Transistor)
Global
IQ10…IQ17
I_.10…I_.17
Safe Input
Global
Q_.10…Q_.17
Nonsafe Output
Local
where “_” is the Pluto number
Failsafe inputs / Indication outputs (not failsafe) / Dynamic outputs
IQ10
IQ11
Power
0V +24V
Pluto bus
CL
IQ12
IQ13
input
ID
Identifier
CH
IQ15
IQ14
IQ16
IA0
B
B
individual failsafe
Transistor output,
Relay output,
individual failsafe
B
B
Inputs, individual failsafe
Q0
IQ17
IA1
IA2
A
IA3
I4
Q1
A
I6
Q2
A
I7
Q3
A
Pluto D20
0-24V
I5
AI
0-10V/4-20mA
DI
AI
DI
AI
DI
AI
DI
AI
DI
DI
DI
DI
I/O overview PLUTO D20