3.3
Preparations
Prepare the installation in good time by checking that the necessary documents and material are
available, as follows:
•
Installation drawings and this manual.
•
Standard tools, torque wrench and instruments.
•
Rust protection, if additional protection is to be given to machined surfaces. Choose TEC-
TYL 511 (Valvoline) or FERRYL (104), for example.
•
Load cells, adapter plates, bearing housings, etc.
•
Screws as listed in
Table 2. page 20
to secure the load cell, and other screws
for bearing housing, etc.
3.4
Adapter Plates
The adapter plates for all load cell types in the PFTL 101 family must be machined and have a
flatness deviation of maximum 0.05 mm, required surface finish should be Ra 3,2.
For PFTL 101A the thickness of the adapter plates should be minimum 30 mm, and for PFTL 101B
35 mm, see
Figure 15. Installation of Adapter Plates and Alignment of Load Cells page 21
Information
When installing PFTL 101AER and PFTL 101BER adapter plates of austenitic steel must be used,
preferably acid resistant or stainless steel.
3.5
Mounting
The instructions below apply to a typical mounting arrangement. Variations are allowed, provided
that the requirements of
3.1 General
are complied with.
If it is necessary to use tubular dowel pins to secure the position of the load cell,
see instructions in
Figure 14. Typical Installation page 21
.
1. Clean the foundation and other mounting surfaces.
2. Fit the lower adapter plate to the load cell. Tighten the screws to the torque stated in
Table 2.
page 20
.
3. Fit the load cell and the lower adapter plate to the foundation, but do not fully tighten the
screws.
4. Fit the upper adapter plate to the load cell. Tighten the screws to the torque stated in
Table 2.
page 20
.
5. Fit the bearing housing and the roll to the upper adapter plate, but do not fully tighten the
screws.
Pressductor PillowBlock Load Cells, Horizontal Measuring PFTL 101, User Manual
3 Installation
3BSE009965R0401 en Rev E
19
Summary of Contents for PFTL 101
Page 41: ......