background image

 

 

 

2UCD074000E418_A 

PCS100 AVC-40-1B                                          

Active Voltage Conditioner 

Roof Kit Assembly Instruction 

 

 

This  installation  instruction  applies  to  the 

PCS100 AVC-40 1B. 

The  illustrations  and  drawings  are  example 

may not apply to all models. 

All  steps  must  be  performed  and  ticked 

during the installation. 

 

 

 

© Copyright 2022 ABB, All rights reserved. 

 

PC

S10

0 A

V

C

-40

 1B

 

225

 k

VA

 to 30

0 k

VA

 

 

Summary of Contents for PCS100 AVC-40-1B

Page 1: ...Instruction This installation instruction applies to the PCS100 AVC 40 1B The illustrations and drawings are example may not apply to all models All steps must be performed and ticked during the installation Copyright 2022 ABB All rights reserved PCS100 AVC 40 1B 225 kVA to 300 kVA ...

Page 2: ...hnology and unrivalled service and support The quality accuracy and performance of the Company s products result from over 100 years experience combined with a continuous program of innovative design and development to incorporate the latest technology Quality Control The products listed in this catalogue are manufactured in an ISO 9001 accredited facility For More Information Further publications...

Page 3: ...ocument number 2UCD740000E418 Issue date 24 3 2022 Revision Rev A Contact information Address ABB Ltd 111 Main North Road Napier New Zealand Website https new abb com ups This Document This document contains information regarding nstallation of the PCS100 AVC 40 1B roof kit Usage This document should be used when installing the PCS100 AVC 40 1B roof kit Who Should Read This Document This document ...

Page 4: ...technische expertise DA Advarsel Farlig elektrisk spænding Se betjeningsvejledningen Frakobl enheden og afbryd strømforsyningen før du arbejder med denne enhed Giv agt Installation må kun foretages af personer med elektroteknisk ekspertise NO Advarsel Farlig spenning Se i bruksanvisningen Koble fra og steng av strømmen før du arbeider på denne enheten Forsiktig Montering skal kun utføres av kvalif...

Page 5: ...niikasta SL Opozorilo Nevarna napetost Glejte navodila za uporabo Pred delom na tej napravi izklopite in zaklenite električno napajanje Pozor Namestitev sme izvesti samo elektrotehnični strokovnjak FR Avertissement Tension dangereuse Consultez les consignes d utilisation Débranchez et verrouillez l alimentation électrique avant d entreprendre des travaux sur cet appareil Attention L installation d...

Page 6: ... Commissioning Engineers All operations on the PCS100 AVC 40 1B must only be carried out by a trained commissioning engineer familiar with the contents of this checklist Hazardous conditions could arise from incorrect adjustment DANGER Stored Charge Stored charge is present after the device is switched off DANGER Protective Covers Normal operation of this product requires any protective covers in ...

Page 7: ...ty Control 2 For More Information 2 Document Information 3 This Document 3 Usage 3 Who Should Read This Document 3 Prerequisites 3 Safety 4 Safety Instructions 4 Safety Notices 6 Roof kit Installation 8 1 1 Tools Required 9 1 2 Roof Kit assembly 10 11 1 1 Assembly Instruction 11 https new abb com ups ...

Page 8: ... top of the enclosures The roof kit option increases the units protection degree to IP21 These are only for indoor use There is a 7 87 200 mm clearance from the enclosure top to the roof kit to allow for ventilation of the transformer enclosure The roof kit will only cover the main enclosure Roof Kit for 1B Frame Size Figure 1 1 PCS100 AVC 40 1B with Roof Kit ...

Page 9: ...the specific figure and represented as follows The values aside the tool picture shows the specific size and torque value to be used Image Description Torque wrench with 16 mm socket Torque wrench with 8 mm socket Socket driver with 8 mm socket Socket driver with 16 mm socket 8mm spanner 16 mm spanner Step ladder ...

Page 10: ...0Wx800D 1 Top Hat support brackets 4 Bolt M16x45 4 Screw M8x16 Hex Torx 4 Washer Schnor M16 4 Washer Flat HDG M16xDia 34mm 3mm thick 4 Table 1 1 PCS100 AVC 40 1B Roof kit parts To The Top Hat Screw M8x 16 Hex Torx To The Front of PCS100 AVC 40 1B To The PCS100 AVC 40 1B Bolt M16x45 a Hat Support Bracket b Top Hat Figure 1 2 PCS100 AVC 40 UL Roof Kit a Hat support brackets b Top hat ...

Page 11: ... Instruction Work from heights Heights have the risk to cause severe harm Make sure to use an appropriate gear such as a ladder while installing the roof kit a Loosen and remove the top four M16 bolts in the PCS100 AVC 40 1B enclosure Retain for reuse Loosen and remove these M16 bolts Figure 1 4 PCS100 AVC 40 1B ...

Page 12: ...100 AVC 40 1B c Use the four M16 rubber washers and schnors supplied with the roof top kit and four M16 bolts you removed to mount the brackets on the PCS100 AVC 40 1B roof d Place the top hat on the four brackets and use four M8 screws Hex Torx to mount the top hat into the brackets e Finished product should look like Figure 1 1 ...

Page 13: ...13 https library abb com ABB Ltd 111 Main North Road 4110 Napier New Zealand abb com UPS Copyright 2022 ABB All rights reserved Specifications subject to change without notice 2UCD074000E418_A ...

Reviews: