3BSE083678
22
Section 3 Installation
Environmental
Temperatures
EN 60068-2-1
EN 60068-2-2
Operating
–40 to +74 °C (–40 to +165 °F)
Storage and
transport
–50 to +85 °C (–58 to +185 °F)
Relative humidity
EN 60068-2-30
Operating
5 to 95 % (non-condensing)
Storage and
transport
5 to 95 % (condensation allowed
outside packaging)
Altitude
Operating
2 000 m/70 kPa
Service life
Operating
10 year
Reliability prediction
(MTBF)
MIL-HDBK-
217F
Operating
1.182.000 hours
Vibration
IEC 60068-2-6
(sine)
Operating
5–9 Hz ±6 mm
9–500 Hz ±2 g
Shock
IEC 60068-2-27
Operating
15 g, 11 ms
Mechanical
Enclosure
EN 60950-1
Plastic
Fire enclosure
Dimension WxHxD
34 x 123 x 121 mm
Weight
0.2 kg
Mounting
DIN-rail
Degree of protection EN 60529
Enclosure
IP21
Cooling
Convection
Configuration
Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX
port, by DIP-switches. Port mirror function is possible to set with DIP-switch. With the port mirror
function active the switch will copy all outgoing traffic to port 1. This can be used to monitor all
traffic going out from the switch. Packets may be discarded if the total throughput exceeds the port
speed of port 1.